BACKGROUND

Rectal division during minimally invasive surgery including robotic assisted surgery remains challenging, with current techniques often requiring multiple stapler firings to achieve effective transection.

AIMS: We propose a novel technique which allows the use of a Contour® Curved Cutter Stapler to achieve rectal division during robotic assisted surgery.

METHODS

The stapler is inserted through the routinely made pfannenstiel incision and a glove, over an Alexis® port used to create an airtight seal.

CONCLUSION

This simple technique enables reliable perpendicular single stapler firing to achieve rectal transection during colorectal robotic assisted surgery without the requirement for any further incisions.

Для цитирования: Sneddon Fraser, Richards Colin H, Oliphant Raymond. Use of the contour ® curved cutter stapler device for rectal transection during robotic assisted surgery.. The surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland. 2024. DOI: 10.1016/j.surge.2024.11.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.