DOI 10.1016/j.radonc.2018.03.032

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2018

Anal and rectal function after intensity-modulated prostate radiotherapy with endorectal balloon.

Krol Robin, McColl Gill M, Hopman Wim P M, Smeenk Robert J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Late anorectal toxicity influences quality of life after external beam radiotherapy (EBRT) for prostate cancer. A daily inserted endorectal balloon (ERB) during EBRT aims to reduce anorectal toxicity. Our goal is to objectify anorectal function over time after prostate intensity-modulated radiotherapy (IMRT) with ERB.

MATERIAL AND

METHODS

Sixty men, irradiated with IMRT and an ERB, underwent barostat measurements and anorectal manometry prior to EBRT and 6 months, one year and 2 years after radiotherapy. Primary outcome measures were rectal distensibility and rectal sensibility in response to stepwise isobaric distensions and anal pressures.

RESULTS

Forty-eight men completed all measurements. EBRT reduced maximal rectal capacity 2 years after EBRT (250 ± 10 mL vs. 211 ± 10 mL; p < 0.001), area under the pressure-volume curve (2878 ± 270 mL mmHg vs. 2521 ± 305 mL mmHg; p = 0.043) and rectal compliance (NS). Sensory pressure thresholds for first sense and first urge (both p < 0.01) increased. Anal maximum pressure diminished after IMRT (p = 0.006).

CONCLUSIONS

Rectal capacity and sensory function are increasingly affected over time after radiotherapy. There is an indication that these reductions are affected less with IMRT + ERB compared to conventional radiation techniques.

Для цитирования: Krol Robin, McColl Gill M, Hopman Wim P M, Smeenk Robert J. Anal and rectal function after intensity-modulated prostate radiotherapy with endorectal balloon.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2018. DOI: 10.1016/j.radonc.2018.03.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.