A Validated 3D Printed Laryngeal Suturing Simulator for Endoscopic Laryngeal Cleft Repair.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Richardson Clare M, Zopf David A, Ikeda Allison K, van Horn Adam, Cohen Katheryn, Nourmohammadi Zahra, Nassar Michel, Park Jason S, Johnson Kaalan E

Аннотация

OBJECTIVES: Endoscopic laryngeal cleft repair (ELCR) with endolaryngeal suturing is an advanced surgical skill. This study objective was to assess the validity of 3-dimensionally (3D) printed laryngeal suturing simulator for ELCR.

STUDY DESIGN: Development and validation of a simulator for ELCR.

METHODS: An ELCR model was developed using 3D printed and readily available materials. Participants were surveyed before and after a simulation session using five-point Likert scale questions. Performance data was assessed using blinded expert video review and rated using a novel objective structured assessment of technical skills (OSATS) for endoscopic laryngeal suturing.

RESULTS: Twenty-one participants ranging from residents to attendings completed the simulation session. Survey respondents reported on a five-point Likert scale that the model was "easy to use" and "quite realistic" (both mean of 4). Confidence improved significantly in 86% of participants (p < 0.01). Overall OSATS scores (out of a total of 55) showed a median improvement in technical skills of 11.7 points (p = 0.004). OSATS demonstrated good intra-rater (κ = 0.689 and 0.677) and moderate inter-rater (κ = 0.573) reliability. Completion times improved from the first to the last suture by a median time of 512 to 350 s (decrease of 202 s, p = 0.002). Participants with no prior ELCR experience improved more than those with in vivo experience.

CONCLUSION: This study demonstrates the validity of a simulator utilizing 3D printed larynges for ELCR. A novel OSATS for endoscopic laryngeal suturing was successfully implemented. Confidence, technical skills, and completion times improved with the use of the model across a variety of participants. Laryngoscope, 133:785-791, 2023.