DOI 10.1159/000524996

Медицинская библиотека · Respiration; international review of thoracic diseases · 2022

Endoscopic Lung Volume Reduction with One-Way Valves in Patients with Severe Chronic Obstructive Pulmonary Disease with Hypercapnia.

Lenga Pavlina, Grah Christian, Ruwwe-Glösenkamp Christoph, Saccomanno Jacopo, Rückert Jens, Eggeling Stephan, Gläser Sven, Kurz Sylke, Eisenmann Stephan, Krüger Marcus, Schmidt Bernd, Schneider Paul, Andreas Stefan, Hinterthaner Marc, Pfannschmidt Joachim, Gebhardt Andreas, Stanzel Franz, Holland Angélique, Kirschbaum Andreas, Becke Birgit, Hübner Ralf-Harto, Lung Emphysema Registry Study Group

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Robust clinical evidence on the efficacy and safety of endoscopic lung volume reduction (ELVR) with one-way valves in patients with severe lung emphysema with chronic hypercapnic respiratory failure is lacking.

OBJECTIVE

The aim of this study was to compare patient characteristics, clinical outcome measures, and incidences of adverse events between patients with severe COPD undergoing ELVR with one-way valves and with either a partial pressure of carbon dioxide (pCO2) of ≤45 mm Hg or with pCO2 >45 mm Hg.

METHODS

This was a multicentre prospective study of patients with severe lung disease who were evaluated based on lung function, exercise capacity (6-min walk test [6-MWT]), and quality-of-life tests.

RESULTS

Patients with pCO2 ≤45 mm Hg (n = 157) and pCO2 >45 mm Hg (n = 40) showed similar baseline characteristics. Patients with pCO2 ≤45 mm Hg demonstrated a significant increase in forced expiratory volume in 1 s (p < 0.001), a significant decrease in residual volume (RV) (p < 0.001), and significant improvements in the quality of life and 6-MWT at the 3-month follow-up. Patients with pCO2 >45 mm Hg had significant improvements in RV only (p < 0.05). There was a significant decrease in pCO2 between baseline and follow-up in hypercapnic patients, relative to the decrease in patients with pCO2 ≤45 mm Hg (p = 0.008). Patients who were more hypercapnic at baseline showed a greater reduction in pCO2 after valve placement (r = -0.38, p < 0.001). Pneumothorax was the most common adverse event in both groups.

CONCLUSIONS

ELVR with one-way valves seems clinically beneficial with a remarkably good safety profile for patients with chronic hypercapnic respiratory failure.

Для цитирования: Lenga Pavlina, Grah Christian, Ruwwe-Glösenkamp Christoph, Saccomanno Jacopo, Rückert Jens, Eggeling Stephan, Gläser Sven, Kurz Sylke, Eisenmann Stephan, Krüger Marcus, Schmidt Bernd, Schneider Paul, Andreas Stefan, Hinterthaner Marc, Pfannschmidt Joachim, Gebhardt Andreas, Stanzel Franz, Holland Angélique, Kirschbaum Andreas, Becke Birgit, Hübner Ralf-Harto, Lung Emphysema Registry Study Group. Endoscopic Lung Volume Reduction with One-Way Valves in Patients with Severe Chronic Obstructive Pulmonary Disease with Hypercapnia.. Respiration; international review of thoracic diseases. 2022. DOI: 10.1159/000524996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.