Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand.

Chaimayo Chutikarn, Kaewnaphan Bualan, Tanlieng Nattaya, Athipanyasilp Niracha, Sirijatuphat Rujipas, Chayakulkeeree Methee, Angkasekwinai Nasikarn, Sutthent Ruengpung, Puangpunngam Nattawut, Tharmviboonsri Theerawoot, Pongraweewan Orawan, Chuthapisith Suebwong, Sirivatanauksorn Yongyut, Kantakamalakul Wannee, Horthongkham Navin

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The Coronavirus disease 2019 (COVID-19) pandemic continues to spread across the world. Hence, there is an urgent need for rapid, simple, and accurate tests to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Performance characteristics of the rapid SARS-CoV-2 antigen detection test should be evaluated and compared with the gold standard real-time reverse transcription-polymerase chain reaction (RT-PCR) test for diagnosis of COVID-19 cases.

METHODS

The rapid SARS-CoV-2 antigen detection test, Standard™ Q COVID-19 Ag kit (SD Biosensor®, Republic of Korea), was compared with the real-time RT-PCR test, Allplex™ 2019-nCoV Assay (Seegene®, Korea) for detection of SARS-CoV-2 in respiratory specimens. Four hundred fifty-four respiratory samples (mainly nasopharyngeal and throat swabs) were obtained from COVID-19 suspected cases and contact individuals, including pre-operative patients at Siriraj Hospital, Bangkok, Thailand during March-May 2020.

RESULTS

Of 454 respiratory samples, 60 (13.2%) were positive, and 394 (86.8%) were negative for SARS-CoV-2 RNA by real-time RT-PCR assay. The duration from onset to laboratory test in COVID-19 suspected cases and contact individuals ranged from 0 to 14 days with a median of 3 days. The rapid SARS-CoV-2 antigen detection test's sensitivity and specificity were 98.33% (95% CI, 91.06-99.96%) and 98.73% (95% CI, 97.06-99.59%), respectively. One false negative test result was from a sample with a high real-time RT-PCR cycle threshold (Ct), while five false positive test results were from specimens of pre-operative patients.

CONCLUSIONS

The rapid assay for SARS-CoV-2 antigen detection showed comparable sensitivity and specificity with the real-time RT-PCR assay. Thus, there is a potential use of this rapid and simple SARS-CoV-2 antigen detection test as a screening assay.

Для цитирования: Chaimayo Chutikarn, Kaewnaphan Bualan, Tanlieng Nattaya, Athipanyasilp Niracha, Sirijatuphat Rujipas, Chayakulkeeree Methee, Angkasekwinai Nasikarn, Sutthent Ruengpung, Puangpunngam Nattawut, Tharmviboonsri Theerawoot, Pongraweewan Orawan, Chuthapisith Suebwong, Sirivatanauksorn Yongyut, Kantakamalakul Wannee, Horthongkham Navin. Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand.. Virology journal. 2020. DOI: 10.1186/s12985-020-01452-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.