DOI 10.1007/s00261-025-05151-z

Медицинская библиотека · Abdominal radiology (New York) · 2025

Multi-institutional study for comparison of detectability of hypovascular liver metastases between 70- and 40-keV images: DELMIO study.

Ichikawa Shintaro, Funayama Satoshi, Hyodo Tomoko, Ozaki Kumi, Ito Akio, Kakuya Masatoshi, Kobayashi Tatsunori, Tanahashi Yukichi, Kozaka Kazuto, Igarashi Saya, Suto Taketo, Noda Yoshifumi, Matsuo Masayuki, Narita Akiko, Okada Hiroaki, Suzuki Kojiro, Goshima Satoshi

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the lesion detectability of hypovascular liver metastases between 70-keV and 40-keV images from dual energy-computed tomography (CT) reconstructed with deep-learning image reconstruction (DLIR).

METHODS

This multi-institutional, retrospective study included adult patients both pre- and post-treatment for gastrointestinal adenocarcinoma. All patients underwent contrast-enhanced CT with reconstruction at 40-keV and 70-keV. Liver metastases were confirmed using gadoxetic acid-enhanced magnetic resonance imaging. Four radiologists independently assessed lesion conspicuity (per-patient and per-lesion) using a 5-point scale. A radiologic technologist measured image noise, tumor-to-liver contrast, and contrast-to-noise ratio (CNR). Quantitative and qualitative results were compared between 70-keV and 40-keV images.

RESULTS

The study included 138 patients (mean age, 69 ± 12 years; 80 men) with 208 liver metastases. Seventy-one patients had liver metastases, while 67 did not. Primary cancer sites included 68 cases of pancreas, 50 colorectal, 12 stomach, and 8 gallbladder/bile duct. No significant difference in per-patient lesion detectability was found between 70-keV images (sensitivity, 71.8-90.1%; specificity, 61.2-85.1%; accuracy, 73.9-79.7%) and 40-keV images (sensitivity, 76.1-90.1%; specificity, 53.7-82.1%; accuracy, 71.7-79.0%) (p = 0.18-> 0.99). Similarly, no significant difference in per-lesion lesion detectability was observed between 70-keV (sensitivity, 67.3-82.2%) and 40-keV images (sensitivity, 68.8-81.7%) (p = 0.20-> 0.99). However, Image noise was significantly higher at 40 keV, along with greater tumor-to-liver contrast and CNRs for both hepatic parenchyma and tumors (p < 0.01).

CONCLUSION

There was no significant difference in hypovascular liver metastases detectability between 70-keV and 40-keV images using the DLIR technology.

Для цитирования: Ichikawa Shintaro, Funayama Satoshi, Hyodo Tomoko, Ozaki Kumi, Ito Akio, Kakuya Masatoshi, Kobayashi Tatsunori, Tanahashi Yukichi, Kozaka Kazuto, Igarashi Saya, Suto Taketo, Noda Yoshifumi, Matsuo Masayuki, Narita Akiko, Okada Hiroaki, Suzuki Kojiro, Goshima Satoshi. Multi-institutional study for comparison of detectability of hypovascular liver metastases between 70- and 40-keV images: DELMIO study.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05151-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.