OBJECTIVE

To compare the size of the fetal thymus, using both fetal thymic-thoracic ratio and fetal thymus transverse diameter values in Assisted reproductive technologies (ART) or naturally conceived pregnancies.

METHODS

In this retrospective study, fetal thymic-thoracic ratio and fetal thymus transverse diameter were evaluated in 204 pregnant women. Patients were examined in two groups. The study included 58 Intracytoplasmic sperm injection (ICSI) patients (study group) and 146 healthy pregnant women (control group).

RESULTS

Fetal thymic-thoracic ratio in ART pregnancies were found to be statistically significantly lower than that of the control group (p = .001). Also, the fetal thymus transverse diameter value was found to be statistically significantly lower in ART pregnancies compared to that of the control group (p = .001).

CONCLUSIONS

The size of the fetal thymus, manifested with a decrease in both fetal thymic-thoracic ratio and thymus transverse diameter values, decreased in ART pregnancies.

Для цитирования: Gök Koray, Ozden Selçuk. Decreased fetal thymus size in pregnancies after assisted reproductive technologies.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2023. DOI: 10.1080/14767058.2023.2166401.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.