Nuclear medicine communications · 2019
Performing clinical 18F-FDG-PET/MRI of the mediastinum optimising a dedicated, patient-friendly protocol.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Peerlings Jurgen, Paulis Leonie, Mitea Cristina, Bakers Frans, Berbée Maaike, Wierts Roel, Vöö Stefan, Wildberger Joachim, Hoffmann Aswin, Lambin Philippe, Mottaghy Felix
Аннотация
OBJECTIVE: To construct a mediastinal-specific fluorine-18-fluorodeoxyglucose (F-FDG)-PET/MR protocol with high-quality MRI of minimal acquisition-time and comparable diagnostic value to F-FDG-PET/computed tomography (CT).
MATERIALS AND METHODS: Fifteen healthy participants received PET/MRI and 10 patients with mediastinal tumours (eight non-small-cell lung, two oesophageal cancer) received F-FDG-PET/MRI immediately after F-FDG-PET/CT. Sequences volume interpolated breath-hold examination (T1-VIBE) and Half-Fourier acquisition single-shot turbo spin echo (T2-HASTE) were optimised by varying the parameters: breath-hold (BH, end-expiration), fat suppression (spectral adiabatic inversion recovery), and ECG-triggering (ECG, end-diastole). Image quality (IQ) of each sequence-variation was qualitatively scored by medical experts and quantitatively assessed by calculating signal-to-noise ratios, contrast relative to muscle, standardized-uptake-value, and tumour-to-blood ratios. Patient comfort was evaluated on patients' experience. Diagnostic accuracy of F-FDG-PET/MRI was compared to F-FDG-PET/CT, in reference to histopathology/cytopathology.
RESULTS: ECG-triggered T1-VIBE images showed the highest signal-to-noise ratio (P < 0.01) and the largest contrast between mediastinal soft-tissues, regardless of BH or free-breathing acquisition. IQ of ECG-triggered T1-VIBE scans in BH were scored qualitatively highest with good reader agreement (κ = 0.62). IQ of T2-HASTE was not significantly affected by BH acquisition (P > 0.9). Qualitative IQ of T1-VIBE and T2-HASTE declined after spectral adiabatic inversion recovery fat-suppression. All patients could maintain BH at end-expiration and reported no discomfort. Diagnostic performance of F-FDG-PET/MR was not significantly different from F-FDG-PET/CT with comparable staging, standardized-uptake-values, and tumour-to-blood ratios. However, T-status was more often over-staged on F-FDG-PET/CT, while N-status was more frequently under-staged on F-FDG-PET/MR.
CONCLUSION: ECG-triggered T1-VIBE sequences acquired during short, multiple BHs are recommended for mediastinal imaging using F-FDG-PET/MR. With dedicated protocols, F-FDG-PET/MRI will be useful in thoracic oncology and aid in diagnostic evaluation and tailored treatment decision-making.
MATERIALS AND METHODS: Fifteen healthy participants received PET/MRI and 10 patients with mediastinal tumours (eight non-small-cell lung, two oesophageal cancer) received F-FDG-PET/MRI immediately after F-FDG-PET/CT. Sequences volume interpolated breath-hold examination (T1-VIBE) and Half-Fourier acquisition single-shot turbo spin echo (T2-HASTE) were optimised by varying the parameters: breath-hold (BH, end-expiration), fat suppression (spectral adiabatic inversion recovery), and ECG-triggering (ECG, end-diastole). Image quality (IQ) of each sequence-variation was qualitatively scored by medical experts and quantitatively assessed by calculating signal-to-noise ratios, contrast relative to muscle, standardized-uptake-value, and tumour-to-blood ratios. Patient comfort was evaluated on patients' experience. Diagnostic accuracy of F-FDG-PET/MRI was compared to F-FDG-PET/CT, in reference to histopathology/cytopathology.
RESULTS: ECG-triggered T1-VIBE images showed the highest signal-to-noise ratio (P < 0.01) and the largest contrast between mediastinal soft-tissues, regardless of BH or free-breathing acquisition. IQ of ECG-triggered T1-VIBE scans in BH were scored qualitatively highest with good reader agreement (κ = 0.62). IQ of T2-HASTE was not significantly affected by BH acquisition (P > 0.9). Qualitative IQ of T1-VIBE and T2-HASTE declined after spectral adiabatic inversion recovery fat-suppression. All patients could maintain BH at end-expiration and reported no discomfort. Diagnostic performance of F-FDG-PET/MR was not significantly different from F-FDG-PET/CT with comparable staging, standardized-uptake-values, and tumour-to-blood ratios. However, T-status was more often over-staged on F-FDG-PET/CT, while N-status was more frequently under-staged on F-FDG-PET/MR.
CONCLUSION: ECG-triggered T1-VIBE sequences acquired during short, multiple BHs are recommended for mediastinal imaging using F-FDG-PET/MR. With dedicated protocols, F-FDG-PET/MRI will be useful in thoracic oncology and aid in diagnostic evaluation and tailored treatment decision-making.