m+Medelevator.RU
← Поиск публикаций
Journal of magnetic resonance imaging : JMRI · 2018

Multicystic mucinous adenocarcinoma of the uterine cervix compared with benign multicystic lesions: Multiparametric MR features.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Song Jiacheng, Hu Qiming, Huang Junwen, Ma Zhanlong, Chen Ting

Аннотация

BACKGROUND: Multicystic mucinous adenocarcinoma is rarely recognized and has a high misdiagnosis rate.

PURPOSE: To distinguish malignant multicystic mucinous adenocarcinomas from benign multicystic lesions in the uterine cervix using multiparametric MR.

STUDY TYPE: Retrospective.

POPULATION: Forty patients with seven cystic mucinous adenocarcinomas and 33 benign multicystic lesions.

FIELD STRENGTH/SEQUENCE: 3.0T. Diffusion-weighted images (DWI) and dynamic contrast-enhanced (DCE) images.

ASSESSMENT: Lesion size, intracystic hemorrhage, solid component, and heterogeneous enhancement were subjectively assessed, and apparent diffusion coefficient (ADC) values, Ktrans , Kep , and Ve parameters were compared.

STATISTICAL ANALYSIS: Student's t-test was used to compare age, tumor size, ADC values, and DCE parameters. Pearson's chi-square test was used to compare intracystic hemorrhage, solid component, and heterogeneous enhancement. Receiver-operating-characteristic (ROC) analysis of ADC values, tumor size, and Ktrans were performed.

RESULTS: The size of mucinous adenocarcinomas was larger than benign multicystic lesions (4.09 ± 2.09 vs. 2.23 ± 0.58 cm, P < 0.001); the area under the curve (AUC) for tumor size was 0.859 with a sensitivity of 71.4% and specificity of 90.9%. Stromal ADC value was lower for mucinous adenocarcinomas (1.19 ± 0.22 vs. 1.68 ± 0.22 × 10-3 mm2 /s, P < 0.001); AUC for stromal ADC value was 0.970, with a sensitivity of 86.4% and specificity of 100.0%. Among quantitative DCE parameters, only ktrans offered a discriminative value (1.72 ± 1.42 vs. 0.69 ± 0.30 min-1 , P = 0.031); the AUC for ktrans was 0.831 with a sensitivity of 71.4% and specificity of 97.0%. Intracystic hemorrhage (3/7), solid component (5/7), and heterogeneous enhancement (4/7) were only found in mucinous adenocarcinomas. Five patients (71.4%) had lymphovascular space invasion and three (42.9%) had lymph node metastasis. The 1-year tumor recurrence or metastasis rate was 28.5% (2/7).

DATA CONCLUSION: Awareness of multiparametric MR features can assist in the differentiation of mucinous adenocarcinomas from benign multicystic lesions.

LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1336-1343.