MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11095-019-2625-4

Медицинская библиотека · Pharmaceutical research · 2019

Contact Lens Based Drug Delivery to the Posterior Segment Via Iontophoresis in Cadaver Rabbit Eyes.

Christopher Keith, Chauhan Anuj

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: A drug loaded contact lens combined with electrodes positioned diametrically opposite and beyond the limbus can potentially deliver ionic drugs directly to the vitreous.

METHODS

Commercial lenses are loaded with nile blue or fluorescein as the drug analogs and placed on cadaver rabbit eyes. Electrodes (19.6 mm2) are placed atop at opposite sides of the sclera to apply a constant current (0.125-0.250 mA) for 1-2 h. COMSOL simulations are conducted to determine the field distribution and the potential drop across various tissue layers and equivalent circuit model is developed to calculate the electrophoretic velocity and estimate the drug flux.

RESULTS

The device delivered both hydrophobic and hydrophilic dyes to the tissue. The amount of fluorescein delivered to the vitreous directly correlated with the applied current and time duration. The electrophoretic mobility from the experimental data agreed with the model estimates. Confocal microscopy showed that nile blue penetrated through the conjunctiva-sclera barrier to reach the retina showing that the electric field can transport molecules through the ocular tissue and into the vitreous. The ex vivo model neglects transport into flowing capillaries in the choroid. However, the time scale for electrophoretic transport across the choroid was found to be 550-1300 fold shorter than that for uptake into the choroidal capillaries.

CONCLUSION

Incorporation of an electric field with multiple electrodes on a single lens can effectively deliver ionic drugs to the posterior region at levels comparable to current methods with the benefits of being safer and less invasive.

Для цитирования: Christopher Keith, Chauhan Anuj. Contact Lens Based Drug Delivery to the Posterior Segment Via Iontophoresis in Cadaver Rabbit Eyes.. Pharmaceutical research. 2019. DOI: 10.1007/s11095-019-2625-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.