1-year outcomes of the Xen45 glaucoma implant.

Smith Michael, Charles Roselin, Abdel-Hay Ahmed, Shah Brinda, Byles Daniel, Lim Lei-Ai, Rossiter Jonathan, Kuo Chih-Hung, Chapman Peter, Robertson Shalini

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To describe the 12-month outcomes of the Xen45 glaucoma stent.

METHODS

Non-comparative retrospective study of all cases who underwent Xen glaucoma surgery in April 2017 or earlier and completed 12 months of follow-up. The primary outcome measures were intraocular pressure (IOP) reduction and number of glaucoma medications at 12 months postoperatively. The secondary outcome measures were surgical complications and the success rate of surgery at 1 year. Success rate was defined according to the multiple IOP thresholds of 15 mmHg, 18 mmHg, and 21 mmHg with all requiring a drop of 20% and no additional glaucoma surgery. Revision or needling of the Xen conjunctival bleb was not considered to constitute a surgical failure.

RESULTS

Sixty-eight eyes were included in the study. Mean IOP dropped from 22.1 mmHg preoperatively to 14.8 mmHg at 12 months, a 33% drop (p < 0.0001). Mean number of glaucoma medications reduced from 2.9 preoperatively to 1.1 at 12 months (p < 0.0001). In total, 54.4% of cases were back on glaucoma medications by 12 months. Success rate varied from 32.4% when defined as IOP ≤ 15 mmHg and ≥ 6 mmHg and ≥ 20% reduction without medications to 70.6% when defined as IOP ≤ 21 mmHg and ≥ 6 mmHg and ≥ 20% reduction with or without medications. Thirty cases (44.1%) required bleb needling or surgical revision.

CONCLUSIONS

The Xen45 is effective at reducing IOP and glaucoma medication use at 12 months postoperatively. Patients considering this procedure should be warned that by 12 months postoperatively there is a significant chance of requiring postoperative bleb intervention and glaucoma drops.

Для цитирования: Smith Michael, Charles Roselin, Abdel-Hay Ahmed, Shah Brinda, Byles Daniel, Lim Lei-Ai, Rossiter Jonathan, Kuo Chih-Hung, Chapman Peter, Robertson Shalini. 1-year outcomes of the Xen45 glaucoma implant.. Eye (London, England). 2018. DOI: 10.1038/s41433-018-0310-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.