ANZ journal of surgery · 2021
Trans-urethral snare stent removal: a novel, self-constructed innovation for simultaneous ureteral stent removal and safety guidewire insertion.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Adam Ahmed, Bhattu Amit S, Lawrentschuk Nathan
Аннотация
BACKGROUND: Ureteral stent insertion and subsequent removal remains one of the most common procedures performed in endourology. We aimed to evaluate a novel, one-step method, permitting simultaneous stent removal and guidewire passage using a self-constructed suture snare via standard cystoscopy. This method should be used prior to ureteroscopy, in cases of minimal stent encrustation and peri-ureteral mucosal oedema, where identification and subsequent cannulation of the ureteral orifice may be a challenge.
METHODS: A self-constructed suture snare is constructed using an open-ended ureteral catheter to facilitate this novel 'Switch' technique. Operative duration, cost feasibility and potential complications with this novel method were assessed in patients with an indwelling stent duration above 100 days.
RESULTS: Age inclusion in this study ranged from 21 to 35 years, with kidney, ureter and bladder scores below 6, in the five patients assessed. Previous ureteral stent indwelling time ranged from 106 to 315 days. Reasons for (pre-stented) ureteroscopy were mostly stone related. The overall recorded procedure time for the Switch technique was successfully performed in less than 96 s (range 68-95 s) in all cases within this series. No procedure-related complications were reported.
CONCLUSION: Utilizing the suture snare, the novel Switch technique was successfully performed in all cases assessed. This method is both time and cost feasible and could be easily utilized in resource-limited areas, regional centres or in cases where a stent grasper is not available, may have malfunctioned or cannot adequately approximate due to distal ureteral stent encrustation.
METHODS: A self-constructed suture snare is constructed using an open-ended ureteral catheter to facilitate this novel 'Switch' technique. Operative duration, cost feasibility and potential complications with this novel method were assessed in patients with an indwelling stent duration above 100 days.
RESULTS: Age inclusion in this study ranged from 21 to 35 years, with kidney, ureter and bladder scores below 6, in the five patients assessed. Previous ureteral stent indwelling time ranged from 106 to 315 days. Reasons for (pre-stented) ureteroscopy were mostly stone related. The overall recorded procedure time for the Switch technique was successfully performed in less than 96 s (range 68-95 s) in all cases within this series. No procedure-related complications were reported.
CONCLUSION: Utilizing the suture snare, the novel Switch technique was successfully performed in all cases assessed. This method is both time and cost feasible and could be easily utilized in resource-limited areas, regional centres or in cases where a stent grasper is not available, may have malfunctioned or cannot adequately approximate due to distal ureteral stent encrustation.