m+Medelevator.RU
← Поиск публикаций
The American journal of case reports · 2020

Utility of the FloTrac™ Sensor for Anesthetic Management of Laparoscopic Surgery in a Patient After Pneumonectomy: A Case Report and Literature Review.

Клинический случайСтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Akazawa Mai, Nakanishi Miho, Miyazaki Narumi, Takahashi Kan, Kitagawa Hirotoshi

Аннотация

BACKGROUND Pneumonectomy is associated with various anatomical changes and potential complications involving the respiratory and cardiovascular systems. How laparoscopic surgery affects cardiorespiratory status in postpneumonectomy patients is yet to be ascertained. Here, we describe the use of the FloTrac™ sensor for the anesthetic management of laparoscopic adrenalectomy in a postpneumonectomy patient. CASE REPORT A 35-year-old woman underwent an extended hysterectomy and right pneumonectomy for retroperitoneal angiosarcoma and lung metastases, respectively. The metastasis was found in her left adrenal gland; therefore, laparoscopic adrenalectomy was scheduled. Spirometry demonstrated the following: forced vital capacity (FVC), 1.90 L (55.6% of predicted value); vital capacity, 53.6%; forced expiratory volume (FEV₁), 1.38 L (47.3% of predicted value); and FEV₁/FVC, 72.4%. The heart and mediastinal structures had shifted into the right hemithorax. Hugh-Jones classification was grade 2. The induction of general anesthesia was planned. The patient was orotracheally intubated and managed with the pressure control ventilation-volume guaranteed mode of ventilation, targeting an expired tidal volume of 6-7 ml/kg, without using PEEP. We evaluated cardiac output (CO), cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) using a FloTrac™ sensor. After the establishment of pneumoperitoneum, SVV increased. CO and SV decreased slightly; however, the patient's hemodynamic status was stable. After surgery, we extubated the patient in the operating room; she demonstrated good progress and was discharged home on postoperative day 5. CONCLUSIONS We found changes in the values of SVV after pneumoperitoneum in a postpneumonectomy patient. The FloTrac™ sensor may be a minimally invasive and promising monitor for detecting hemodynamic changes associated with laparoscopic surgery in postpneumonectomy patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты