MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1098612x20974962

Медицинская библиотека · Journal of feline medicine and surgery · 2020

Ultrasonographic evaluation of adrenal gland size in two body weight categories of healthy adult cats.

Pérez-López Laura, Wägner Ana María, Saavedra Pedro, Jaber Jose Raduan, Melián Carlos

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Adrenal gland size and its association with body weight have been rarely evaluated in cats. This study was undertaken to assess the association between feline body weight and adrenal gland thickness, and to propose reference intervals (RIs) for adrenal gland thickness in healthy cats.

METHODS

This was a cross-sectional study in which 39 healthy cats were included. The cats were divided into two weight categories, classified as ⩽4.0 kg and >4-8 kg of ideal body weight (with 13 and 26 cats in each group, respectively), which took into consideration the body condition score of the cats. All cats underwent an ultrasound examination that was taken from a subcostal position. Maximum dorsoventral thicknesses of the left (MTL) and right (MTR) adrenal glands were measured in a sagittal plane. RIs were obtained for the maximum thickness (MT), which included the MTLs and MTRs of each cat. RIs with the 90% confidence intervals were calculated according to American Society for Veterinary Clinical Pathology guidelines on RIs.

RESULTS

No statistical differences for adrenal gland thickness were observed between the left and right (P = 0.543) adrenal glands or between male and female cats (P = 0.943). Mean MT was significantly greater in the group of cats weighing >4-8 kg compared with the group of cats weighing ⩽4 kg (3.7 ± 0.6 vs 3.2 ± 0.4 mm; P <0.005). The lower limit of the RI for MT was 2.4 mm (range 2.2-2.6 mm) in the group weighing ⩽4 kg and 2.6 mm (range 2.4-2.8 mm) in the group weighing >4-8 kg. The upper limit of the RI for MT was 3.9 mm (range 3.7-4.1 mm) in the group of cats weighing ⩽4 kg and 4.8 mm (range 4.6-5.1 mm) in the group of cats weighing >4-8 kg.

CONCLUSIONS AND RELEVANCE: The use of RIs based on two group sizes allows for a more accurate ultrasonographic evaluation of adrenal gland thickness in cats. The maximum normal adrenal gland thickness is lower in smaller cats (3.9 mm for those weighing ⩽4 kg and 4.8 mm for those weighing >4-8 kg).

Для цитирования: Pérez-López Laura, Wägner Ana María, Saavedra Pedro, Jaber Jose Raduan, Melián Carlos. Ultrasonographic evaluation of adrenal gland size in two body weight categories of healthy adult cats.. Journal of feline medicine and surgery. 2020. DOI: 10.1177/1098612x20974962.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.