Primary stability of turned and acid-etched screw-type implants: a removal torque and histomorphometric study in rabbits.
Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fernandes Eduardo de Lima, Unikowski Ieda Levenzon, Teixeira Eduardo Rolim, da Costa Nilza Pereira, Shinkai Rosemary Sadami
Аннотация
PURPOSE: This study evaluated the effect of primary stability on the osseointegration of turned and acid-etched screw implants in a rabbit model.
MATERIALS AND METHODS: One pair of turned and acid-etched implants (3.75 in diameter, 5.5 mm long) was placed in each tibia of 15 rabbits. In the right tibial metaphysis the implants were inserted according to a standard surgical protocol. In the left tibia, the osteotomy sites were enlarged using a sequence of drills, and 2 implants were placed with reduction of primary stability. Animals were sacrificed 9 weeks after surgery. Histomorphometric and removal torque analyses were performed to evaluate bone-implant contact and strength of osseointegration.
RESULTS: Surface texture had a significant effect on percentage of bone-implant contact (P = .001). Acid-etched implants with high primary stability showed the highest percentage of bone-implant contact (77%), followed by acid-etched implants with low primary stability (61%), turned implants with low primary stability (56%), and turned implants with high primary stability (46%). For removal torque, acid-etched implants had higher peak mean values than turned implant groups (P < .001). Reduction of primary stability was not significant to either percentage of bone-implant contact (P = .645) or removal torque values (P = .214).
CONCLUSION: Acid-etched implants had higher bone response and implant fixation than turned implants, regardless of primary stability.
MATERIALS AND METHODS: One pair of turned and acid-etched implants (3.75 in diameter, 5.5 mm long) was placed in each tibia of 15 rabbits. In the right tibial metaphysis the implants were inserted according to a standard surgical protocol. In the left tibia, the osteotomy sites were enlarged using a sequence of drills, and 2 implants were placed with reduction of primary stability. Animals were sacrificed 9 weeks after surgery. Histomorphometric and removal torque analyses were performed to evaluate bone-implant contact and strength of osseointegration.
RESULTS: Surface texture had a significant effect on percentage of bone-implant contact (P = .001). Acid-etched implants with high primary stability showed the highest percentage of bone-implant contact (77%), followed by acid-etched implants with low primary stability (61%), turned implants with low primary stability (56%), and turned implants with high primary stability (46%). For removal torque, acid-etched implants had higher peak mean values than turned implant groups (P < .001). Reduction of primary stability was not significant to either percentage of bone-implant contact (P = .645) or removal torque values (P = .214).
CONCLUSION: Acid-etched implants had higher bone response and implant fixation than turned implants, regardless of primary stability.