MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.05-0039

Медицинская библиотека · Investigative ophthalmology & visual science · 2005

Noncontact optical measurement of lens capsule thickness in human, monkey, and rabbit postmortem eyes.

Ziebarth Noël M, Manns Fabrice, Uhlhorn Stephen R, Venkatraman Anna S, Parel Jean-Marie

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To measure interspecies thickness differences in the central anterior and posterior capsules of postmortem crystalline lenses, by a technique that maintains the anatomic integrity of the lens.

METHODS

Central capsule thickness was measured with a custom-built, noncontact optical system, using a focus detection technique. Anterior and posterior lens capsule thickness measurements were performed on 22 human, 29 monkey, and 34 New Zealand White rabbit intact postmortem lenses in situ. Eyes were prepared for optical measurements by bonding a PMMA ring to the sclera in the region of the ciliary body after the conjunctiva, adipose, and muscle tissues were removed. The posterior pole was removed by making a circumferential incision through the sclera approximately 7 mm posterior to the limbus. Excess vitreous was removed to expose the posterior capsule surface, and the eye assembly was placed on a Teflon slide. The cornea and iris were sectioned to expose the anterior capsule surface. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Lens capsule thickness was measured from the histologic slides and compared to the optical

RESULTS

results. Central anterior lens capsule thickness was 8.2 +/- 5.5 (human), 7.5 +/- 4.4 (monkey), and 10.7 +/- 4.2 (rabbit) microm optically and 12.4 +/- 2.5 (human), 10.7 +/- 3.7 (monkey), and 10.4 +/- 2.0 (rabbit) microm histologically. Central posterior capsule thickness was 6.3 +/- 2.2 (human), 5.9 +/- 1.7 (monkey), and 7.8 +/- 2.3 (rabbit) microm optically and 4.1 +/- 1.5 (human), 3.5 +/- 1.6 (monkey), and 4.7 +/- 2.5 (rabbit) microm histologically.

CONCLUSIONS

The central anterior and posterior lens capsule thicknesses do not appear to vary considerably among human, rabbit, and monkey eyes. There were significant differences between optical in situ measurements and histology, which indicates that histologic preparation may affect lens capsule thickness.

Для цитирования: Ziebarth Noël M, Manns Fabrice, Uhlhorn Stephen R, Venkatraman Anna S, Parel Jean-Marie. Noncontact optical measurement of lens capsule thickness in human, monkey, and rabbit postmortem eyes.. Investigative ophthalmology & visual science. 2005. DOI: 10.1167/iovs.05-0039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.