MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081-597x-20050101-09

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2005

Potentially accommodating intraocular lenses--an in vitro and in vivo study using three-dimensional high-frequency ultrasound.

Stachs Oliver, Schneider Hanka, Stave Joachim, Guthoff Rudolf

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the accommodative performance of new intraocular lenses (IOL) using the advantages of three-dimensional ultrasound biomicroscopy.

METHODS

An in vitro simulation device was designed to study IOL performance using an artificial capsular bag and a stretching device. The haptic region of the Akkommodative 1CU (HumanOptics AG) and CrystaLens AT-45 (Eyeonics Inc) was visualized in vitro in three dimensions, using an in-house developed three-dimensional ultrasound biomicroscope. The in vitro results were used to describe the in vivo situation in four patients with accommodative implants.

RESULTS

The haptic position and angulation in consideration of the accommodation state was distinguished and analyzed. In the simulation model, a maximal angulation change of 4.5 degrees and 4.3 degrees and a maximal forward shift of 0.33 mm and 0.28 mm was observed for the AT-45 and 1CU, respectively. In vivo, a change in haptic angulation <100 and a maximal forward shift of 0.50 mm was observed for the 1CU. These changes correspond to a theoretical approximate value of 0.50 diopters.

CONCLUSIONS

The in vitro simulation device examined with three-dimensional ultrasound biomicroscopy provided information on the accommodative performance of these potentially accommodative IOL designs. Using three-dimensional ultrasound biomicroscopy, corresponding changes in haptic angulation during pharmacological-induced accommodation were observed.

Для цитирования: Stachs Oliver, Schneider Hanka, Stave Joachim, Guthoff Rudolf. Potentially accommodating intraocular lenses--an in vitro and in vivo study using three-dimensional high-frequency ultrasound.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2005. DOI: 10.3928/1081-597x-20050101-09.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.