DOI 10.1371/journal.pone.0122838
Intra-operative tissue oxygen tension is increased by local insufflation of humidified-warm CO2 during open abdominal surgery in a rat model.
Аннотация
INTRODUCTION
Maintenance of high tissue oxygenation (PtO2) is recommended during surgery because PtO2 is highly predictive of surgical site infection and colonic anastomotic leakage. However, surgical site perfusion is often sub-optimal, creating an obstructive hurdle for traditional, systemically applied therapies to maintain or increase surgical site PtO2. This research tested the hypothesis that insufflation of humidified-warm CO2 into the abdominal cavity would increase sub-peritoneal PtO2 during open abdominal surgery.
MATERIALS AND
METHODS
15 Wistar rats underwent laparotomy under general anesthesia. Three sets of randomized cross-over experiments were conducted in which the abdominal cavity was subjected to alternating exposure to 1) humidified-warm CO2 & ambient air; 2) humidified-warm CO2 & dry-cold CO2; and 3) dry-cold CO2 & ambient air. Sub-peritoneal PtO2 and tissue temperature were measured with a polarographic oxygen probe.
RESULTS
Upon insufflation of humidified-warm CO2, PtO2 increased by 29.8 mmHg (SD 13.3; p<0.001), or 96.6% (SD 51.9), and tissue temperature by 3.0°C (SD 1.7 p<0.001), in comparison with exposure to ambient air. Smaller, but significant, increases in PtO2 were seen in experiments 2 and 3. Tissue temperature decreased upon exposure to dry-cold CO2 compared with ambient air (-1.4°C, SD 0.5, p = 0.001).
CONCLUSIONS
In a rat model, insufflation of humidified-warm CO2 into the abdominal cavity during open abdominal surgery causes an immediate and potentially clinically significant increase in PtO2. The effect is an additive result of the delivery of CO2 and avoidance of evaporative cooling via the delivery of the CO2 gas humidified at body temperature.