MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2007.26.12.1681

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2007

Ultrasonographic serial measurements of the morphologic resolution of the pylorus after Ramstedt pyloromyotomy for infantile hypertrophic pyloric stenosis.

Muramori Katsumi, Nagasaki Akira, Kawanami Takashi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purposes of this study were to evaluate the accuracy of the ultrasonographic measurements used during diagnosis of hypertrophic pyloric stenosis (HPS), to examine the relationship between the palpability and the morphologic features of the pyloric mass, and to show the morphologic resolution of the pylorus after pyloromyotomy.

METHODS

One hundred three infants with the diagnosis of HPS by clinical findings and ultrasonographic measurements were treated surgically by Ramstedt pyloromyotomy. The measurement parameters were the muscle thickness, diameter, and channel length of the pylorus. The serial measurements were performed postoperatively for 1 year after surgery.

RESULTS

The preoperative ultrasonographic measurements of the pylorus were significantly correlated with the actual measurements obtained by surgery (P<.05). The diameter correlated most significantly with the palpability of the pylorus. In contrast to the prompt improvement of clinical symptoms, the muscle thickness did not reach the normal range (approximately 2 mm) until 8 months after surgery. The diameter had not decreased to its normal range (approximately 10 mm) by the end of the 1-year postoperative follow up period. The channel length decreased more rapidly than the other 2 parameters.

CONCLUSIONS

The preoperative ultrasonographic measurements of the pylorus reliably evaluated the pyloric muscle thickness and diameter in HPS. The actual pyloric diameter correlated with the palpability of the pyloric mass. The morphologic resolution of the pylorus after surgery did not correlate with the prompt improvement of symptoms.

Для цитирования: Muramori Katsumi, Nagasaki Akira, Kawanami Takashi. Ultrasonographic serial measurements of the morphologic resolution of the pylorus after Ramstedt pyloromyotomy for infantile hypertrophic pyloric stenosis.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2007. DOI: 10.7863/jum.2007.26.12.1681.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.