MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jmau.jmau_53_22

Медицинская библиотека · Journal of microscopy and ultrastructure · 2022

ImageJ-FIJI-Assisted Estimation of Intestinal Layers' Volume: Study in Jejunum-Ileum of Rats.

Wicaksono Satrio Adi, Sumiwi Yustina Andwi Ari, Paramita Dewi Kartikawati, Susilowati Rina

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Studies in the digestive tract often required precision quantification of intestinal volume to observe the effect of certain intervention/condition. Application of stereological methods could bring unbiased and accurate results but commercially computer-assisted systems are not widely available. ImageJ-FIJI is an open source software, which could become an alternative choice in the stereological measurement process.

AIM: This study describes simple stereological quantification methods during volume estimation of jejunum-ileum intestinal layers of the rats using a light microscope and ImageJ-FIJI stereological tool.

MATERIAL AND

METHODS

Six 3-months old male Sprague-Dawley rats were terminated and jejunum-ileum was harvested after perfusion. After removal of intestinal luminal content, whole jejunum-ileum weight was measured. The organ was sampled as 6-10 slabs of 1 cm length in a systematic uniformed random sampling manner. Slabs were cut longitudinally at random angles before flattened and put on filter papers for subsequent tissue processing into 2-3 paraffin blocks. One section of 3 μm thick was sampled from each block, stained using toluidine blue and documented using a light microscope connected to a microstepper apparatus. The volume of the intestinal layers was estimated using a point-counting grid on Image J-FIJI software.

RESULT: We compared two sets of counting methods i.e. minimal counting (MC) and rigorous counting (RC) approaches that differ in their respective a/p value. Quantification using RC approach resulted in significantly higher estimated volume of tunica submucosa and tunica muscularis while having more preferable stereological accuracy parameters (CE<5% & CV<10%).

CONCLUSION

Although it required longer counting time, rigorous approaches resulted in higher accuracy while still within the range of rule of thumb criteria of 0.2 < CE2/CV2 < 0.5.

Для цитирования: Wicaksono Satrio Adi, Sumiwi Yustina Andwi Ari, Paramita Dewi Kartikawati, Susilowati Rina. ImageJ-FIJI-Assisted Estimation of Intestinal Layers' Volume: Study in Jejunum-Ileum of Rats.. Journal of microscopy and ultrastructure. 2022. DOI: 10.4103/jmau.jmau_53_22.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.