Ex vivo and in vivo evaluation of a modified interrupted Lembert pattern for small intestinal anastomoses in horses.

Seitz-Cherner Emma, Bauck Anje G, Denagamage Thomas, Freeman David E

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare single-layer anastomoses (modified continuous Lembert [mod-CL] and modified-interrupted Lembert [mod-IL]) and a 2-layer simple continuous anastomosis (2 L; seromuscular and mucosal) for jejunojejunal anastomoses in equine cadavers and to compare ex vivo to in vivo time to complete the anastomosis and stoma size with a mod-IL pattern.

STUDY

DESIGN

Measurements in jejunum from cadaver and anesthetized horses.

ANIMALS: Ten live horses and 18 equine cadavers.

METHODS

Time to complete anastomosis, bursting pressures (BP), leakage sites, and anastomotic index (size ratio of anastomotic lumen to control lumen) were recorded. Time to completion and lumen size were compared between in vivo and ex vivo mod-IL patterns.

RESULTS

The mod-CL pattern was fastest (8.44 ± 1.30 min, p < .05), and the 2 L pattern was slower (17.07 ± 2.0 min) than the mod-CL and mod-IL (p < .05). The anastomotic index exceeded 100 and did not differ between patterns. Segments reached higher bursting pressures when anastomosed with mod-IL (145.94 ± 24.18 mm Hg) than mod-CL (p < .05). In vivo closure was approximately 8 minutes slower than ex vivo, and with a smaller anastomotic index.

CONCLUSIONS

All anastomoses increased lumen size over control segments ex vivo. Lumen size after placement of a mod-IL was greater ex vivo than in vivo, and completion was slower in vivo than ex vivo. [Corrections added on 26 Dec 2022, after online publication: added "ex vivo" to the first line of Conclusions in the Abstract.] CLINICAL SIGNIFICANCE: Slower and smaller anastomoses should be anticipated in vivo compared to ex vivo results. Anastomoses with a mod-IL pattern appear clinically advantageous, producing a comparable lumen size in less time than 2 L.

Для цитирования: Seitz-Cherner Emma, Bauck Anje G, Denagamage Thomas, Freeman David E. Ex vivo and in vivo evaluation of a modified interrupted Lembert pattern for small intestinal anastomoses in horses.. Veterinary surgery : VS. 2022. DOI: 10.1111/vsu.13881.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.