MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2015/684976

Медицинская библиотека · Case reports in nephrology · 2015

A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique.

Kumar Santosh, Singh Shivanshu, Sharma Aditya Prakash, Rathi Manish

СтатьяПеревод пока не подготовлен

Аннотация

CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully managed by laparoscopic hanging loop technique. This case report highlights the ease with which epiplopexy can be performed and catheter tip migration can be prevented by this innovative laparoscopic procedure.

Для цитирования: Kumar Santosh, Singh Shivanshu, Sharma Aditya Prakash, Rathi Manish. A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique.. Case reports in nephrology. 2015. DOI: 10.1155/2015/684976.