Clinical application of navigator-gated three-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 1.5 T.
Аннотация
OBJECTIVE
To evaluate and compare the clinical utility of balanced turbo-field-echo (BTFE) magnetic resonance cholangiopancreatography (MRCP) sequences obtained at 3 and 1.5 T.
METHODS
We acquired three-dimensional (3D) BTFE MRCP scans with a navigator-gated technique at 3 T on a different day after 1.5 T in 39 consecutive patients. Two radiologists independently rated the image quality and visibility of anatomical structures (right and left hepatic duct, cystic duct, gallbladder, common bile duct, and main pancreatic duct) using a four-point scale. For quantitative analysis, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and acquisition time were evaluated.
RESULTS
All visual scores tended to be higher for 1.5 T than 3 T images. There was a significant difference in the image quality and the depiction of the main pancreatic duct (p < 0.01). The image acquisition time was significantly shorter for 3 T than 1.5 T (199.3 ± 40.1 vs. 264.0 ± 86.5 s, p < 0.01). There was no significant difference in SNR and CNR.
CONCLUSIONS
3D-BTFE MRCP scans acquired at 3 T were of sufficient image quality with respect to the biliary tree. SNR and CNR were comparable on 3 and 1.5 T scans, although the acquisition time was significantly shorter with the 3 T scanner.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.