MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0190770

Медицинская библиотека · PloS one · 2018

Computed tomography-based volumetric tool for standardized measurement of the maxillary sinus.

Giacomini Guilherme, Pavan Ana Luiza Menegatti, Altemani João Mauricio Carrasco, Duarte Sergio Barbosa, Fortaleza Carlos Magno Castelo Branco, Miranda José Ricardo de Arruda, de Pina Diana Rodrigues

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Volume measurements of maxillary sinus may be useful to identify diseases affecting paranasal sinuses. However, literature shows a lack of consensus in studies measuring the volume. This may be attributable to different computed tomography data acquisition techniques, segmentation methods, focuses of investigation, among other reasons. Furthermore, methods for volumetrically quantifying the maxillary sinus are commonly manual or semiautomated, which require substantial user expertise and are time-consuming. The purpose of the present study was to develop an automated tool for quantifying the total and air-free volume of the maxillary sinus based on computed tomography images. The quantification tool seeks to standardize maxillary sinus volume measurements, thus allowing better comparisons and determinations of factors that influence maxillary sinus size. The automated tool utilized image processing techniques (watershed, threshold, and morphological operators). The maxillary sinus volume was quantified in 30 patients. To evaluate the accuracy of the automated tool, the results were compared with manual segmentation that was performed by an experienced radiologist using a standard procedure. The mean percent differences between the automated and manual methods were 7.19% ± 5.83% and 6.93% ± 4.29% for total and air-free maxillary sinus volume, respectively. Linear regression and Bland-Altman statistics showed good agreement and low dispersion between both methods. The present automated tool for maxillary sinus volume assessment was rapid, reliable, robust, accurate, and reproducible and may be applied in clinical practice. The tool may be used to standardize measurements of maxillary volume. Such standardization is extremely important for allowing comparisons between studies, providing a better understanding of the role of the maxillary sinus, and determining the factors that influence maxillary sinus size under normal and pathological conditions.

Для цитирования: Giacomini Guilherme, Pavan Ana Luiza Menegatti, Altemani João Mauricio Carrasco, Duarte Sergio Barbosa, Fortaleza Carlos Magno Castelo Branco, Miranda José Ricardo de Arruda, de Pina Diana Rodrigues. Computed tomography-based volumetric tool for standardized measurement of the maxillary sinus.. PloS one. 2018. DOI: 10.1371/journal.pone.0190770.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.