MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jemermed.2009.11.005

Медицинская библиотека · The Journal of emergency medicine · 2010

A new maneuver for endotracheal tube insertion during difficult GlideScope intubation.

Walls Ron M, Samuels-Kalow M, Perkins A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The GlideScope Video Laryngoscope (Verathon, Bothell, WA) is a video laryngoscopy system that can be used for routine intubation, but is also commonly used as an alternative for difficult or failed airways. Previous reports have identified a very high incidence of grade 1 and grade 2 Cormack-Lehane glottic views, but despite these high-grade views, intubation is sometimes difficult due to the angle of insertion and shape of the endotracheal tube. Several maneuvers have been reported to increase the likelihood of successful endotracheal tube placement in these uncommon cases of failure.

CASE REPORT: We report the case of a patient who could not be intubated with the GlideScope despite an easily obtained grade 1 laryngoscopic view. The impediment to intubation was identified as a sharp angulation of the trachea with respect to the larynx, such that the trachea formed a steep posterior angle with the laryngeal/glottic axis. Intubation was achieved using a previously unreported maneuver, in which the endotracheal tube with a sharply curved malleable stylet was inserted through the glottis, and then rotated 180 degrees to permit passage down the trachea.

DISCUSSION AND

CONCLUSION

We believe that this maneuver may be useful in other cases of failed GlideScope intubation, when a high-grade laryngeal view is obtained but tube passage is not possible due to a sharp posterior angulation of the trachea.

Для цитирования: Walls Ron M, Samuels-Kalow M, Perkins A. A new maneuver for endotracheal tube insertion during difficult GlideScope intubation.. The Journal of emergency medicine. 2010. DOI: 10.1016/j.jemermed.2009.11.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.