MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.14271

Медицинская библиотека · Veterinary surgery : VS · 2025

Accuracy of computer-assisted drilling of equine cervical vertebral bodies using a purpose-built cervical frame-An experimental cadaveric study.

Maurer Thimo, de Preux Mathieu, Precht Christina, Vidondo Beatriz, Koch Christoph

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the accuracy of computer-assisted surgery (CAS) of equine cervical vertebrae using a purpose-built cervical frame (CF) for neck stabilization.

STUDY

DESIGN

Experimental cadaveric study.

SAMPLE POPULATION: Six whole fresh equine cadavers.

METHODS

Cadavers were positioned in dorsal recumbency with the neck extended within the CF. A cone-beam computed tomography (CBCT)-based surgical navigation system with optical tracking was used. A ventral approach exposed cervical vertebrae C3-C5. In each cadaver, 12 drill corridors were prepared with the patient tracker on the CF (position CF), followed by 12 corridors with the patient tracker on C3 (position C3). Surgical accuracy aberration (SAA) was assessed by measuring Euclidean distances between planned and executed entry and target points on merged pre- and postoperative datasets. Descriptive statistics and repeated-measures analyses of variance (rep.-meas. ANOVA) compared SAA measurements between groups.

RESULTS

The mean ± SD SAA (Euclidean distance) was 2.00 ± 0.98 mm in patient tracker position CF, and 2.41 ± 1.31 mm in position C3 (rep.-meas. ANOVA p = .215). At the most dorsal point of the drill corridor, dorsoventral deviations >2 mm occurred in 5/72 measurements in patient tracker position CF, and in 12/72 measurements in position C3.

CONCLUSION

The CF allowed for unrestricted pre- and intraoperative CBCT imaging and computer-assisted drilling with a SAA in the close range of 2 mm. Positioning the patient tracker on the CF, outside the surgical field, did not compromise surgical accuracy.

CLINICAL SIGNIFICANCE: A CF can facilitate CAS for surgeries with a ventral approach to the equine cervical vertebral column.

Для цитирования: Maurer Thimo, de Preux Mathieu, Precht Christina, Vidondo Beatriz, Koch Christoph. Accuracy of computer-assisted drilling of equine cervical vertebral bodies using a purpose-built cervical frame-An experimental cadaveric study.. Veterinary surgery : VS. 2025. DOI: 10.1111/vsu.14271.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.