MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2022.105181

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2022

The influence of the tertiary bronchi on dynamic lung deformation.

Brannen MacKenzie, Kang Gia, Dutrisac Scott, Banton Rohan, Clayton John D, Petel Oren E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Finite element models of thoracic injury often treat the lung as a bulk homogeneous and isotropic material, which reduces the computational costs associated with such investigations. Ignoring the heterogeneous structure of the lung may be computationally expedient, but this simplification may inadvertently fail to capture the true lung strain dynamics. In the present work, a series of direct impact experiments were performed on porcine lungs, inflated to a relevant expiratory pressure, and monitored using high-speed X-ray imaging. The lungs were instrumented with radiopaque markers within the parenchyma and tertiary bronchi to monitor the resulting deformation mechanics. The deformation mechanics demonstrate a high degree of strain localization related to the structural heterogeneity of the lung. The relative motion of the tertiary bronchi was measured during the impact event, and used to estimate the parenchyma tissue strains in the inter-bronchial regions. These were shown to exceed the trans-lobe strains by a factor 3 to 5 times higher in their tensile, compressive, and shear strain responses. Our results demonstrate that the lung parenchyma and bronchial tissues form a heterogeneous structure with a substantial stiffness differential that cannot be appropriately modelled as a homogeneous and isotropic monolithic mass without loss of accuracy and predictive relevance.

Для цитирования: Brannen MacKenzie, Kang Gia, Dutrisac Scott, Banton Rohan, Clayton John D, Petel Oren E. The influence of the tertiary bronchi on dynamic lung deformation.. Journal of the mechanical behavior of biomedical materials. 2022. DOI: 10.1016/j.jmbbm.2022.105181.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.