MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2024.106720

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2024

Biomechanical simulation of segmented intrusion of a mandibular canine using Robot Orthodontic Measurement & Simulation System (ROSS).

Sabbagh Hisham, Dotzer Benedikt, Baumert Uwe, Hötzel Linus, Seidel Corinna Lesley, Wichelhaus Andrea

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Aim of this study was to investigate the forces and moments during segmented intrusion of a mandibular canine using Cantilever-Intrusion-Springs (CIS).

METHODS

Three different CIS modifications were investigated using a robotic biomechanical simulation system: unmodified CIS (#1, control), CIS with a lingual directed 6° toe-in bend (#2), and CIS with an additional 20° twist bend (#3). Tooth movement was simulated by the apparative robotic stand, controlled by a force-control algorithm, recording the acting forces and moments with a force-torque sensor. Statistical analysis was performed using Shapiro-Wilk, Kolmogorov-Smirnov, Kruskal-Wallis ANOVA and post hoc tests with Bonferroni correction (α = 0.05).

RESULTS

The initial intrusive force, which was uniformly generated by a 35° Tip-Back bend, decreased significantly (p < 0.05) from 0.31 N in group (#1) to 0.28 N in group (#3). Vestibular crown tipping reduced significantly (p < 0.05) from 2.11° in group (#1) and 1.72° in group (#2) to 0.05° in group (#3). Matching to that the direction of orovestibular force significantly (p < 0.05) shifted from 0.15 N to vestibular in group (#1) to 0.51 N to oral in group (#3) and the orovestibular tipping moment decreased also significantly (p < 0.05) from 4.63 Nmm to vestibular in group (#1) to 3.56 Nmm in group (#2) and reversed to 1.20 Nmm to oral in group (#3). Apart from that the orovestibular displacement changed significantly (p < 0.05) from 0.66 mm in buccal direction in group (#1) to 0.29 mm orally in group (#2) and 1.49 mm in oral direction as well in group (#3).

SIGNIFICANCE: None of the modifications studied achieved pure mandibular canine intrusion without collateral effects. The significant lingual displacement caused by modification (#3) is, not least from an aesthetic perspective, considered much more severe than a slight tipping of the canine. Consequently, modification (#2) can be recommended for clinical application based on the biomechanical findings.

Для цитирования: Sabbagh Hisham, Dotzer Benedikt, Baumert Uwe, Hötzel Linus, Seidel Corinna Lesley, Wichelhaus Andrea. Biomechanical simulation of segmented intrusion of a mandibular canine using Robot Orthodontic Measurement & Simulation System (ROSS).. Journal of the mechanical behavior of biomedical materials. 2024. DOI: 10.1016/j.jmbbm.2024.106720.