MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12917-024-04221-6

Медицинская библиотека · BMC veterinary research · 2024

A forecasting model for suitable dental implantation in canine mandibular premolar region based on finite element analysis.

Liu Ruiyu, Yang Jie, Zhu Yiling, Zhou Xiaoxiao, Zhou Qiaolin, Liang Ting, Wang Huan, Luo Yan, Xie Yue, Liu Haifeng, Zhong Zhijun, Peng Guangneng, Zhuang Hao, Ai Shengquan, Jiang Lingxue, Zheng Chengli, Zhou Ziyao

СтатьяПеревод пока не подготовлен

Аннотация

In recent years, dental implants have become a trend in the treatment of human patients with missing teeth, which may also be an acceptable method for companion animal dentistry. However, there is a gap challenge in determining appropriate implant sizes for different dog breeds and human. In this study, we utilized skull computed tomography data to create three-dimensional models of the mandibles of dogs in different sizes. Subsequently, implants of various sizes were designed and subjected to biomechanical finite element analysis to determine the optimal implant size. Regression models were developed, exploring the relationship between the average weight of dogs and the size of premolar implants. Our results illustrated that the regression equations for mean body weight (x, kg) and second premolar (PM2), third premolar (PM3), and fourth premolar (PM4) implant length (y, mm) in dogs were: y = 0.2785x + 7.8209, y = 0.2544x + 8.9285, and y = 0.2668x + 10.652, respectively; the premolar implant diameter (mm) y = 0.0454x + 3.3506, which may provide a reference for determine suitable clinical implant sizes for dogs.

Для цитирования: Liu Ruiyu, Yang Jie, Zhu Yiling, Zhou Xiaoxiao, Zhou Qiaolin, Liang Ting, Wang Huan, Luo Yan, Xie Yue, Liu Haifeng, Zhong Zhijun, Peng Guangneng, Zhuang Hao, Ai Shengquan, Jiang Lingxue, Zheng Chengli, Zhou Ziyao. A forecasting model for suitable dental implantation in canine mandibular premolar region based on finite element analysis.. BMC veterinary research. 2024. DOI: 10.1186/s12917-024-04221-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.