MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-024-05862-5

Медицинская библиотека · Clinical oral investigations · 2024

Assessment of the bony resection margin distance in bone-invasive oral cancer using laser-induced breakdown spectroscopy.

Winnand Philipp, Ooms Mark, Heitzer Marius, Vohl Nils, Lammert Matthias, Hölzle Frank, Boernsen K Olaf, Modabber Ali

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Inadequate resection margins of less than 5 mm impair local tumor control. This weak point in oncological safety is exacerbated in bone-infiltrating tumors because rapid bone analysis procedures do not exist. This study aims to assess the bony resection margin status of bone-invasive oral cancer using laser-induced breakdown spectroscopy (LIBS).

MATERIALS AND

METHODS

LIBS experiments were performed on natively lasered, tumor-infiltrated mandibular cross-sections from 10 patients. In total, 5,336 spectra were recorded at defined distances from the tumor border. Resection margins < 1 mm were defined as very close, from 1-5 mm as close, and > 5 mm as clear. The spectra were histologically validated. Based on the LIBS spectra, the discriminatory power of potassium (K) and soluble calcium (Ca) between bone-infiltrating tumor tissue and very close, close, and clear resection margins was determined.

RESULTS

LIBS-derived electrolyte emission values of K and soluble Ca as well as histological parameters for bone neogenesis/fibrosis and lymphocyte/macrophage infiltrates differ significantly between bone-infiltrating tumor tissue spectra and healthy bone spectra from very close, close, and clear resection margins (p < 0.0001). Using LIBS, the transition from very close resection margins to bone-infiltrating tumor tissue can be determined with a sensitivity of 95.0%, and the transition from clear to close resection margins can be determined with a sensitivity of 85.3%.

CONCLUSIONS

LIBS can reliably determine the boundary of bone-infiltrating tumors and might provide an orientation for determining a clear resection margin.

CLINICAL RELEVANCE: LIBS could facilitate intraoperative decision-making and avoid inadequate resection margins in bone-invasive oral cancer.

Для цитирования: Winnand Philipp, Ooms Mark, Heitzer Marius, Vohl Nils, Lammert Matthias, Hölzle Frank, Boernsen K Olaf, Modabber Ali. Assessment of the bony resection margin distance in bone-invasive oral cancer using laser-induced breakdown spectroscopy.. Clinical oral investigations. 2024. DOI: 10.1007/s00784-024-05862-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.