OBJECTIVES

To conduct a finite element analysis of the impact of different variables on tooth sectioning efficiency and trauma to surrounding tissues when utilizing high-speed surgical handpieces and elevators.

METHODS

CBCT data from the horizontally impacted third mandibular molar (M3M) of a patient were utilized to establish digital models of the M3M, adjacent M2M, and surrounding bone. To simulate tooth sectioning, a 3D finite element model was established with the following variables: remaining tooth tissue thickness (1-5 mm), tooth section fissure width (1-3 mm), elevator depth in fissure (2-6 mm), elevator position (buccal, lingual, central), elevator width (2-5 mm), and application of force (rotating, levering). Using this model, the distribution of stress on the M3M and the surrounding tissue was assessed while measuring tooth sectioning efficiency and trauma to the surrounding tissue.

RESULTS

Factors associated with uniform stress at the site of sectioning included thin (≤ 3 mm) remaining tooth tissue, appropriate fissure width (~ 2 mm), a wide (≥ 4 mm) elevator, and central elevator positioning. Levering the elevator yielded greater stress on the M3M than rotating force. Greater sectioning efficiency was associated with increased stress placed on the distobuccal side of M2M.

CONCLUSIONS

Tooth sectioning efficiency can be improved by adjusting the high-speed surgical handpiece and elevator. However, it is important to remain attentive to the trauma to which adjacent teeth are exposed during this process.

CLINICAL SIGNIFICANCE: These results offer guidance for approaches to improving operator efficiency and reducing trauma to surrounding tissues during tooth sectioning.

Для цитирования: Yan Zi-Yu, Xu Jin-Yang, Zhang Jing-Yu, Li Qing-Xiang, Chen Liang-Wei, Wu Bin-Zhang, Cui Nian-Hui. Optimal tooth sectioning using a surgical handpiece and elevator: a finite element study of horizontally deeply impacted mandibular third molars.. Clinical oral investigations. 2024. DOI: 10.1007/s00784-024-05834-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.