Determination of testicular function after torsion by DNA flow cytometry of serial fine-needle aspirates.

Carroll T A, Regan M C, Alyusuf R, Greene D, Curran B, Kay E, Leader M, Fitzpatrick J M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the efficacy of DNA flow cytometric analysis of testicular percutaneous fine-needle aspirates in the assessment and follow-up of testicular function after torsion, and to determine the relationship between the duration of torsion and testicular injury.

MATERIALS AND

METHODS

Three groups of 15 adult rats underwent a 720 degrees torsion, with fixation of the mesorchial ligament, for 1, 3 or 5 h. Bilateral aspirations, performed 7, 21 and 35 days after torsion were examined by flow cytometry. Testes were harvested and evaluated histologically using Johnsen's scoring.

RESULTS

Irreversible testicular injury occurred in all three groups of rats, with loss of function after 1 h and loss of viability after 3 and 5 h. The results from flow cytometry suggested significant contralateral testicular injury (P < 0.025) but this was not supported by the histological evaluation. There was a strong correlation between the testicular function assessed by flow cytometry and by Johnsen's scoring of histological specimens (r2 = 0.95).

CONCLUSION

The assessment of testicular aspirates by flow cytometry allows testicular function to be followed after torsion in rats, and potentially in humans. Using DNA flow cytometry, the temporal course of the twisted testis in the adult rat was determined; contralateral testicular injury following the reversal of torsion could not be excluded.

Для цитирования: Carroll T A, Regan M C, Alyusuf R, Greene D, Curran B, Kay E, Leader M, Fitzpatrick J M. Determination of testicular function after torsion by DNA flow cytometry of serial fine-needle aspirates.. British journal of urology. 1997. DOI: 10.1046/j.1464-410x.1997.09825.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.