DOI 10.1038/s41433-025-03679-4
Normative data for dimensions of the frontal and infraorbital nerves.
Аннотация
OBJECTIVES
To present a series of normative measurements for the width of the frontal and infraorbital nerve branches of V1 and V2, respectively.
METHODS
Cadaveric dissection study of 15 embalmed cadaver heads (30 orbits). The frontal nerve was excised en bloc from the superior orbital rim to the superior orbital fissure. Similarly, the infraorbital nerve was excised en bloc from the inferior orbital rim to the orbital apex. Measurements were recorded of the maximal width of the frontal nerve, infraorbital nerve within the orbital floor, and pterygopalatine segment of the maxillary nerve. Any value greater than 2 standard deviations (SD) above the mean value, was defined as nerve enlargement.
RESULTS
The mean transverse diameter of the frontal nerve was 2.27 ± 0.66 mm (1 SD). The mean transverse diameter of the infraorbital nerve branch, and the maxillary nerve within the pterygopalatine fossa, was 3.31 ± 0.68 mm (1 SD) and 3.59 ± 0.76 mm (1 SD), respectively. The upper limit of normal, defined as 2 SD above the mean value, for the widths of the frontal nerve, infraorbital nerve, and pterygopalatine segment of V2 widths were 3.59 mm, 4.67 mm, and 5.10 mm, respectively.
CONCLUSIONS
The frontal and infraorbital nerves are implicated in various inflammatory and neoplastic orbital pathologies. Defining the normative data for width is important to compare with pathological states.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.