MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0000000000001788

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2021

Assessment of Tactile Sensitivity Threshold Using Cochet-Bonnet Esthesiometer and Semmes-Weinstein Monofilaments and Their Use in Corneal Neurotization.

Vinee Frédéric, Grobnicu Oana, Errera Charlotte, Gomart Gabrielle, Tuzin Nicolas, Heitz Antoine, Liverneaux Philippe, Bourcier Tristan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Although the Cochet-Bonnet esthesiometer (CBE) measures corneal sensitivity, it has heretofore only been tested on the index pulp. Tactile skin sensitivity thresholds are measured with Semmes-Weinstein monofilaments (SWM). This study measured skin sensitivity thresholds in healthy individuals using CBE and SWM, and compared both instruments in territories involved in corneal neurotization.

METHODS

Overall, 27 healthy individuals were tested by a single examiner at 9 territories on the face, neck, forearm, and leg, using 20-thread SWM and CBE with a diameter of 0.12 mm. Both sides were tested. Thresholds were compared for both instruments and between the different territories using Bayesian methods.

RESULTS

Mean sensitivity levels for SWM ranged from 0.010 to 1.128 g, while mean sensitivity levels for CBE ranged from 0.006 to 0.122 g. Thresholds measured with SWM were significantly higher than with CBE. Both instruments demonstrated higher thresholds in the leg territory than the forearm. However, the forearm presented higher thresholds than the head territories. No significant differences were found between the head territories themselves. Overall, right-side territories exhibited lower thresholds than left-side territories.

CONCLUSIONS

We have reported the first mapping of skin sensitivity thresholds using CBE. Thresholds measured with CBE and SWM were coherent. The use of CBE on the skin is particularly relevant to the field of corneal neurotization.

Для цитирования: Vinee Frédéric, Grobnicu Oana, Errera Charlotte, Gomart Gabrielle, Tuzin Nicolas, Heitz Antoine, Liverneaux Philippe, Bourcier Tristan. Assessment of Tactile Sensitivity Threshold Using Cochet-Bonnet Esthesiometer and Semmes-Weinstein Monofilaments and Their Use in Corneal Neurotization.. Ophthalmic plastic and reconstructive surgery. 2021. DOI: 10.1097/iop.0000000000001788.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.