Head and neck multi-organ auto-segmentation on CT images aided by synthetic MRI.

Liu Yingzi, Lei Yang, Fu Yabo, Wang Tonghe, Zhou Jun, Jiang Xiaojun, McDonald Mark, Beitler Jonathan J, Curran Walter J, Liu Tian, Yang Xiaofeng

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Because the manual contouring process is labor-intensive and time-consuming, segmentation of organs-at-risk (OARs) is a weak link in radiotherapy treatment planning process. Our goal was to develop a synthetic MR (sMR)-aided dual pyramid network (DPN) for rapid and accurate head and neck multi-organ segmentation in order to expedite the treatment planning process.

METHODS

Forty-five patients' CT, MR, and manual contours pairs were included as our training dataset. Nineteen OARs were target organs to be segmented. The proposed sMR-aided DPN method featured a deep attention strategy to effectively segment multiple organs. The performance of sMR-aided DPN method was evaluated using five metrics, including Dice similarity coefficient (DSC), Hausdorff distance 95% (HD95), mean surface distance (MSD), residual mean square distance (RMSD), and volume difference. Our method was further validated using the 2015 head and neck challenge data.

RESULTS

The contours generated by the proposed method closely resemble the ground truth manual contours, as evidenced by encouraging quantitative results in terms of DSC using the 2015 head and neck challenge data. Mean DSC values of 0.91 ± 0.02, 0.73 ± 0.11, 0.96 ± 0.01, 0.78 ± 0.09/0.78 ± 0.11, 0.88 ± 0.04/0.88 ± 0.06 and 0.86 ± 0.08/0.85 ± 0.1 were achieved for brain stem, chiasm, mandible, left/right optic nerve, left/right parotid, and left/right submandibular, respectively.

CONCLUSIONS

We demonstrated the feasibility of sMR-aided DPN for head and neck multi-organ delineation on CT images. Our method has shown superiority over the other methods on the 2015 head and neck challenge data results. The proposed method could significantly expedite the treatment planning process by rapidly segmenting multiple OARs.

Для цитирования: Liu Yingzi, Lei Yang, Fu Yabo, Wang Tonghe, Zhou Jun, Jiang Xiaojun, McDonald Mark, Beitler Jonathan J, Curran Walter J, Liu Tian, Yang Xiaofeng. Head and neck multi-organ auto-segmentation on CT images aided by synthetic MRI.. Medical physics. 2020. DOI: 10.1002/mp.14378.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.