MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0194599820941017

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2020

Validation of a Sensor-Fitted Simulator for Upper Airway Examination.

Díez Nieves, Pacheco Sofía, Llorente Marcos, Fernández Secundino

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To validate a simulator for upper airway examination, fitted with sensors, for use as an academic tool for learning how to conduct examination of the upper airway and for evaluation of that learning.

STUDY

DESIGN

Validation study.

SETTING

Undergraduate medical education.

SUBJECTS AND

METHODS

A group of 18 fifth-year medical students and another of 6 otorhinolaryngology specialists conducted 6 examinations each with the simulator. To investigate concurrent validity, we calculated the correlation between damage scores provided by the simulator and damage assessment by a specialist. To evaluate construct validity, we compared both groups with regard to damage scores, technical procedure, and time spent. To examine content and face validity, we used questionnaires based on a 5-point Likert scale.

RESULTS

For concurrent validity, the correlation between the simulator's damage scores and the specialist's damage assessment was high: Spearman's ρ was 0.828 (P < .001). For construct validity, the group of students differed from the group of specialists in damage scores (P = .027) and in technical procedures (P < .001) but not in time spent. For content validity, all questionnaire statements were scored highly, and both groups had similar average scores. For face validity, the group of specialists considered the simulator to be realistic, and all statements on the questionnaire were rated with at least 4/5.

CONCLUSION

Concurrent, construct, content, and face validity have been demonstrated for a sensor-fitted simulator for upper airway examination, which is therefore accurate enough to be used as an academic tool for learning and evaluation of learning.

Для цитирования: Díez Nieves, Pacheco Sofía, Llorente Marcos, Fernández Secundino. Validation of a Sensor-Fitted Simulator for Upper Airway Examination.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2020. DOI: 10.1177/0194599820941017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.