MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11701-024-02196-y

Медицинская библиотека · Journal of robotic surgery · 2025

The use of laser-assisted cart positioning significantly reduces the docking time of multimodular robotic systems.

Baunacke Martin, Hirtsiefer Christopher, Herout Roman, Mehralivand Sherif, Oelkers Susanne, Kaske Oliver, Franz Claudia, Thomas Christian

СтатьяПеревод пока не подготовлен

Аннотация

The Hugo RAS system is characterized by its multimodular design, which leads to an increased docking effort. Exact data for docking time and the learning curve is missing. We describe for the first time the use of a laser-guided cart positioning to reduce the docking time. In this prospective monocentric study, the docking time was evalutated for a consecutive series of pelvic surgeries with the Hugo RAS system. In a subgroup, a cross-line laser was adapted at the cart for positioning using fix points at the ceiling. The medical personnel were classified as "inexperienced" with ≤ 5 consecutive dockings and as "experienced" with > 5 consecutive dockings. From 10/2023 to 08/2024, 82 procedures were performed with the Hugo RAS. For the evaluation 75 procedures could be considered. The mean docking time was 7.6 ± 3.5 min. There was a reduction in docking time from 13.5 ± 3.7 min in the first 5 procedures to 4.4 ± 0.9 min in the last 5 procedures (p < 0.001). Docking with laser (n = 45) was faster than without laser (n = 30) (6.2 ± 2.5 vs. 9.8 ± 3.7 min, p < 0.001). Faster docking time was observed with inexperienced surgical nursing staff with laser than without laser (10.4 ± 3.7 vs. 5.4 ± 1.4 min; p < 0.001). With experienced nursing staff, the laser had no influence (6.6 ± 1.3 vs. 6.7 ± 2.9 min; p = 0.9). As a reference docking time for daVinci Xi procedures was 2.4 ± 1.7 min (n = 5). Laser-guided cart positioning has a significant impact on docking time, especially for unexperienced medical personnel. Especially in the times of experienced staff shortage, laser-guided cart positioning can save operating time.

Для цитирования: Baunacke Martin, Hirtsiefer Christopher, Herout Roman, Mehralivand Sherif, Oelkers Susanne, Kaske Oliver, Franz Claudia, Thomas Christian. The use of laser-assisted cart positioning significantly reduces the docking time of multimodular robotic systems.. Journal of robotic surgery. 2025. DOI: 10.1007/s11701-024-02196-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.