MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.tipsro.2024.100295

Медицинская библиотека · Technical innovations & patient support in radiation oncology · 2024

Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images.

Alshammari Shorug S, Yaddanapudi Sridhar, Kušnik Blaž, Ivančič Rok, Anderle Kristjan, Li Jonathan G, Furutani Keith M, Beltran Chris J, Lu Bo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We evaluated and benchmarked a novel deformable image registration (DIR) software functionality (DirOne, Cosylab d.d., Ljubljana, Slovenia) by comparing it to two commercial systems, MIM and VelocityAI, following AAPM task group 132 (TG-132) guidelines.

METHODS

Three publicly available datasets were used for evaluation. The first dataset includes primary and deformed phantom images for a male pelvis. The second, from DIR-Lab, contains ten sets of 4D CT thoracic scans. The third dataset, from the DIR Evaluation Project (DIREP), includes ten head and neck CTs. VelocityAI and MIM served as benchmarks to assess DirOne's performance. Target registration error (TRE), dice similarity coefficient (DSC), and mean distance to agreement (MDA) were the evaluation metrics.

RESULTS

For TRE, the average results for DirOne, MIM, and VelocityAI were 3.3 ± 3.1 mm, 2.7 ± 3.7 mm, and 3.4 ± 2.4 mm, respectively. For DSC, DirOne achieved 0.96 ± 0.02, MIM 0.98 ± 0.02, and VelocityAI 0.98 ± 0.01 across the first and second datasets. In the DIREP dataset, DirOne achieved 0.73 ± 0.34 for MDA and 0.91 ± 0.03 for DSC; MIM achieved 0.54 ± 0.36 and 0.93 ± 0.02, and VelocityAI 0.93 ± 0.38 and 0.90 ± 0.03.

CONCLUSION

The novel DIR software demonstrated clinically acceptable accuracy compared to other commercial systems, supporting its potential use in radiotherapy treatment planning applications such as automatic image segmentation, 4D segmentation propagation, and dose warping.

Для цитирования: Alshammari Shorug S, Yaddanapudi Sridhar, Kušnik Blaž, Ivančič Rok, Anderle Kristjan, Li Jonathan G, Furutani Keith M, Beltran Chris J, Lu Bo. Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images.. Technical innovations & patient support in radiation oncology. 2024. DOI: 10.1016/j.tipsro.2024.100295.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.