MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/nn102274q

Медицинская библиотека · ACS nano · 2010

Noninvasive photoacoustic and fluorescence sentinel lymph node identification using dye-loaded perfluorocarbon nanoparticles.

Akers Walter J, Kim Chulhong, Berezin Mikhail, Guo Kevin, Fuhrhop Ralph, Lanza Gregory M, Fischer Georg M, Daltrozzo Ewald, Zumbusch Andreas, Cai Xin, Wang Lihong V, Achilefu Samuel

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

The contrast mechanisms used for photoacoustic tomography (PAT) and fluorescence imaging differ in subtle, but significant, ways. The design of contrast agents for each or both modalities requires an understanding of the spectral characteristics as well as intra- and intermolecular interactions that occur during formulation. We found that fluorescence quenching that occurs in the formulation of near-infrared (NIR) fluorescent dyes in nanoparticles results in enhanced contrast for PAT. The ability of the new PAT method to utilize strongly absorbing chromophores for signal generation allowed us to convert a highly fluorescent dye into an exceptionally high PA contrast material. Spectroscopic characterization of the developed NIR dye-loaded perfluorocarbon-based nanoparticles for combined fluorescence and PA imaging revealed distinct dye-dependent photophysical behavior. We demonstrate that the enhanced contrast allows detection of regional lymph nodes of rats in vivo with time-domain optical and photoacoustic imaging methods. The results further show that the use of fluorescence lifetime imaging, which is less dependent on fluorescence intensity, provides a strategic approach to bridge the disparate contrast reporting mechanisms of fluorescence and PA imaging methods.

Для цитирования: Akers Walter J, Kim Chulhong, Berezin Mikhail, Guo Kevin, Fuhrhop Ralph, Lanza Gregory M, Fischer Georg M, Daltrozzo Ewald, Zumbusch Andreas, Cai Xin, Wang Lihong V, Achilefu Samuel. Noninvasive photoacoustic and fluorescence sentinel lymph node identification using dye-loaded perfluorocarbon nanoparticles.. ACS nano. 2010. DOI: 10.1021/nn102274q.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.