DOI 10.1007/s11604-025-01759-9
CZT-based photon-counting-detector CT with deep-learning reconstruction: image quality and diagnostic confidence for lung tumor assessment.
Аннотация
PURPOSE: This is a preliminary analysis of one of the secondary endpoints in the prospective study cohort. The aim of this study is to assess the image quality and diagnostic confidence for lung cancer of CT images generated by using cadmium-zinc-telluride (CZT)-based photon-counting-detector-CT (PCD-CT) and comparing these super-high-resolution (SHR) images with conventional normal-resolution (NR) CT images.
MATERIALS AND
METHODS
Twenty-five patients (median age 75 years, interquartile range 66-78 years, 18 men and 7 women) with 29 lung nodules overall (including two patients with 4 and 2 nodules, respectively) were enrolled to undergo PCD-CT. Three types of images were reconstructed: a 512 × 512 matrix with adaptive iterative dose reduction 3D (AIDR 3D) as the NRAIDR3D image, a 1024 × 1024 matrix with AIDR 3D as the SHRAIDR3D image, and a 1024 × 1024 matrix with deep-learning reconstruction (DLR) as the SHRDLR image. For qualitative analysis, two radiologists evaluated the matched reconstructed series twice (NRAIDR3D vs. SHRAIDR3D and SHRAIDR3D vs. SHRDLR) and scored the presence of imaging findings, such as spiculation, lobulation, appearance of ground-glass opacity or air bronchiologram, image quality, and diagnostic confidence, using a 5-point Likert scale. For quantitative analysis, contrast-to-noise ratios (CNRs) of the three images were compared.
RESULTS
In the qualitative analysis, compared to NRAIDR3D, SHRAIDR3D yielded higher image quality and diagnostic confidence, except for image noise (all P < 0.01). In comparison with SHRAIDR3D, SHRDLR yielded higher image quality and diagnostic confidence (all P < 0.01). In the quantitative analysis, CNRs in the modified NRAIDR3D and SHRDLR groups were higher than those in the SHRAIDR3D group (P = 0.003, <0.001, respectively).
CONCLUSION
In PCD-CT, SHRDLR images provided the highest image quality and diagnostic confidence for lung tumor evaluation, followed by SHRAIDR3D and NRAIDR3D images. DLR demonstrated superior noise reduction compared to other reconstruction methods.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.