MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.breast.2009.09.011

Медицинская библиотека · Breast (Edinburgh, Scotland) · 2009

Debating the mathematical model to validate the sentinel lymph biopsy techniques in breast cancer patients. The danger of bias and its practical implications.

Martinez-Ramos David, Escrig-Sos Javier, Alcalde-Sanchez Miguel, Hoashi Jane S, Salvador-Sanchis Jose Luis

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Sentinel node biopsy (SNB) is an effective alternative to axillary lymph node dissection (ALD) for axillary staging. SNB (test) needs a validation period in which ALD (the gold standard) is always performed. Sensitivity, specificity and predictive values (PV) are used to define the accuracy of the procedure. We hypothesise that, during the period of validation, a bias is produced if the result of SNB is included as a part of the ALD.

PATIENTS AND

METHODS

A hypothetical population of 350 patients was analysed. First analyses were performed by including the sentinel lymph node as a part of 'the rest of the axilla'. Second analyses were re-done according to our theory, and sentinel lymph node was considered outside 'the rest of the axilla'. Sensitivity, specificity and PV were compared for both models.

RESULTS

First group (classic) - sensitivity: 94%; specificity: 100%; positive PV: 100%; negative PV: 97%. Second group (new proposed model) - sensitivity: 87%; specificity: 81%; positive PV: 44%; negative PV: 97%.

CONCLUSION

The classic concept of sentinel lymph node to calculate sensitivity, specificity and positive PV can result in a bias. The magnitude of this bias will vary in terms of the obtained values, but its direction is always optimistic.

Для цитирования: Martinez-Ramos David, Escrig-Sos Javier, Alcalde-Sanchez Miguel, Hoashi Jane S, Salvador-Sanchis Jose Luis. Debating the mathematical model to validate the sentinel lymph biopsy techniques in breast cancer patients. The danger of bias and its practical implications.. Breast (Edinburgh, Scotland). 2009. DOI: 10.1016/j.breast.2009.09.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.