MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/js9.0000000000002308

Медицинская библиотека · International journal of surgery (London, England) · 2025

Augmented reality guided versus computed tomography guided percutaneous lung nodule localization: a noninferiority randomized clinical trial.

Song Zuodong, Li Yin, Tian Qing, Sun Chao, Liu Hongfeng, Chong Kongyong, Zhang Qian, Chen Jianeng, Li Pengchong, Song Liwei, Tosi Davide, Kim Min P, Lin Zhebing, Luo Qingquan, Yu Lingming, Cheng Xinghua

СтатьяРандомизированное исследованиеСравнительное исследованиеEquivalence TrialПеревод пока не подготовлен

Аннотация

HYPOTHESIS: This study hypothesized that augmented reality (AR) technology has comparable accuracy and safety to conventional CT localization in guiding percutaneous transthoracic lung puncture (PTLP) to localize small pulmonary nodules.

METHODS

This study was a prospective, non-inferiority randomized clinical trial. Patients were randomly assigned between 23 May 2023, and 26 September 2023. Patients with small peripheral lung nodules (≤2 cm) were recruited. Patients were randomly assigned to either the CT-guided PTLP group or the AR-guided PTLP group, with a 1:1 allocation ratio. The primary outcome was the accuracy of lung nodule localization measured by localization error. The secondary outcomes included procedure duration, radiation exposure dosage and complications.

RESULTS

A total of 70 patients underwent either CT- or AR-guided lung nodule localization and subsequent surgeries. Localization error was smaller in the AR-guided group than in the CT-guided group (mean ± SD, 3.1 ± 4.0 mm vs. 5.4 ± 4.2 mm, P = 0.026). The mean difference of localization errors was -2.3 mm (95% CI: - 4.2 to -0.3 mm, P < 0.001 for non-inferiority). Compared to the CT-guided group, the AR-guided group demonstrated significantly lower radiation exposure (mean ± SD, 421 ± 168 vs. 694 ± 229 mGy × cm, P < 0.001) and shorter localization procedure duration (mean ± SD, 8.8 ± 2.3 vs. 14.1 ± 1.8 minutes, P < 0.001), with no statistical difference in complications.

CONCLUSIONS

The accuracy of the AR-guided approach is comparable to that of the CT-guided approach in localizing small lung nodules. Furthermore, the utilization of AR technology has been demonstrated to reduce procedural time and minimize radiation exposure for patients.

Для цитирования: Song Zuodong, Li Yin, Tian Qing, Sun Chao, Liu Hongfeng, Chong Kongyong, Zhang Qian, Chen Jianeng, Li Pengchong, Song Liwei, Tosi Davide, Kim Min P, Lin Zhebing, Luo Qingquan, Yu Lingming, Cheng Xinghua. Augmented reality guided versus computed tomography guided percutaneous lung nodule localization: a noninferiority randomized clinical trial.. International journal of surgery (London, England). 2025. DOI: 10.1097/js9.0000000000002308.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.