MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1182/asheducation-2016.1.156

Медицинская библиотека · Hematology. American Society of Hematology. Education Program · 2016

Molecular monitoring in chronic myeloid leukemia-how low can you go?

Branford Susan

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Molecular monitoring of BCR-ABL1 transcripts for patients with chronic myeloid leukemia (CML) is now used to assess response to tyrosine kinase inhibitors (TKIs), including treatment failure that mandates a change of therapy. Therefore, many centers have adopted the molecular technique for measuring BCR-ABL1 and rely on conversion of values to the international reporting scale for appropriate clinical interpretation. However, the technique has a degree of inherent variability despite standardized procedures, which means care should be taken by the clinician when assessing response based on BCR-ABL1 cutoff limits. The last few years have witnessed the emergence of a new molecular response target, which is the achievement and maintenance of a deep molecular response. The ability to achieve treatment-free remission for some patients has shifted the relevant boundary for molecular response. However, the definitive safe BCR-ABL1 transcript level and length of the maintenance phase after which treatment cessation can be attempted has not yet been determined. For patients with TKI resistance, BCR-ABL1 kinase domain mutation analysis remains an essential assessment to guide therapy. Furthermore, low-level mutation detection is clinically relevant for response prediction to subsequent TKI therapy for some patients. Multiple low-level mutations may be a biomarker of a clonally diverse disease with the propensity for resistance evolution. Overall, molecular monitoring, including low-level monitoring is a fundamental component of management for patients with CML.

Для цитирования: Branford Susan. Molecular monitoring in chronic myeloid leukemia-how low can you go?. Hematology. American Society of Hematology. Education Program. 2016. DOI: 10.1182/asheducation-2016.1.156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.