MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.leukres.2016.08.007

Медицинская библиотека · Leukemia research · 2016

Cepheid xpert monitor platform for the confirmation of BCR-ABL1 IS conversion factors for the molecular monitoring of chronic myeloid leukaemia.

Gerrard Gareth, Foong Hui En, Mudge Katherine, Alikian Mary, Apperley Jane F, Foroni Letizia

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Molecular monitoring of BCR-ABL1 expression in chronic myeloid leukaemia (CML) is well established. As the International Scale (IS) normalised BCR-ABL1/ABL1 ratio at 3 months post-treatment is now an important milestone in patients' treatment schedule, the reliable and reproducible measurement of BCR-ABL1 levels is therefore paramount. IS conversion factors (CF) are established via sample exchange and yearly ratification with an external reference laboratory. Since any change to an established IS CF could lead to discontinuity in longitudinal results, we wished to add an internal verification step as an additional safeguard. We used the Cepheid GeneXpert qPCR and IS calibrated Xpert BCR-ABL Monitor cartridge system, parallel to our in-house pipeline on 50 CML samples, over the period of one week to verify the CF for those samples and compare it to the externally provided CF. The median non-IS in-house BCR-ABL1/ABL1 values were significantly different than that from the IS GeneXpert, but they became non-significant when adjusted to CF provided by the CXM and by the current external CF, validating it. These metrics can help decide to accept or reject an updated CF value, especially where a significant change in CF might lead to a discontinuity in ongoing patient monitoring.

Для цитирования: Gerrard Gareth, Foong Hui En, Mudge Katherine, Alikian Mary, Apperley Jane F, Foroni Letizia. Cepheid xpert monitor platform for the confirmation of BCR-ABL1 IS conversion factors for the molecular monitoring of chronic myeloid leukaemia.. Leukemia research. 2016. DOI: 10.1016/j.leukres.2016.08.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.