Evaluating Automatic Segmentation for Swallowing-Related Organs for Head and Neck Cancer.

Li Yimin, Rao Shyam, Chen Wen, Azghadi Soheila F, Nguyen Ky Nam Bao, Moran Angel, Usera Brittni M, Dyer Brandon A, Shang Lu, Chen Quan, Rong Yi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Purpose: To evaluate the accuracy of deep-learning-based auto-segmentation of the superior constrictor, middle constrictor, inferior constrictor, and larynx in comparison with a traditional multi-atlas-based method. Methods and Materials: One hundred and five computed tomography image datasets from 83 head and neck cancer patients were retrospectively collected and the superior constrictor, middle constrictor, inferior constrictor, and larynx were analyzed for deep-learning versus multi-atlas-based segmentation. Eighty-three computed tomography images (40 diagnostic computed tomography and 43 planning computed tomography) were used for training the convolutional neural network, and for atlas-based model training. The remaining 22 computed tomography datasets were used for validation of the atlas-based auto-segmentation versus deep-learning-based auto-segmentation contours, both of which were compared with the corresponding manual contours. Quantitative measures included Dice similarity coefficient, recall, precision, Hausdorff distance, 95th percentile of Hausdorff distance, and mean surface distance. Dosimetric differences between the auto-generated contours and manual contours were evaluated. Subjective evaluation was obtained from 3 clinical observers to blindly score the autosegmented structures based on the percentage of slices that require manual modification.

Results

The deep-learning-based auto-segmentation versus atlas-based auto-segmentation results were compared for the superior constrictor, middle constrictor, inferior constrictor, and larynx. The mean Dice similarity coefficient values for the 4 structures were 0.67, 0.60, 0.65, and 0.84 for deep-learning-based auto-segmentation, whereas atlas-based auto-segmentation has Dice similarity coefficient results at 0.45, 0.36, 0.50, and 0.70, respectively. The mean 95th percentile of Hausdorff distance (cm) for the 4 structures were 0.41, 0.57, 0.59, and 0.54 for deep-learning-based auto-segmentation, but 0.78, 0.95, 0.96, and 1.23 for atlas-based auto-segmentation results, respectively. Similar mean dose differences were obtained from the 2 sets of autosegmented contours compared to manual contours. The dose-volume discrepancies and the average modification rates were higher with the atlas-based auto-segmentation contours.

Conclusion

Swallowing-related structures are more accurately generated with DL-based versus atlas-based segmentation when compared with manual contours.

Для цитирования: Li Yimin, Rao Shyam, Chen Wen, Azghadi Soheila F, Nguyen Ky Nam Bao, Moran Angel, Usera Brittni M, Dyer Brandon A, Shang Lu, Chen Quan, Rong Yi. Evaluating Automatic Segmentation for Swallowing-Related Organs for Head and Neck Cancer.. Technology in cancer research & treatment. 2022. DOI: 10.1177/15330338221105724.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.