PURPOSE: This study evaluated the accuracy of a commercial deep learning (DL)-based algorithm for segmenting the prostate, seminal vesicles (SV), and organs at risk (OAR) in patients with prostate cancer.

METHODS

Ten patients with prostate cancer were selected to compare automated and manual segmentation. The prostate, SV, and OAR, including the bladder, rectum, left and right femoral heads, and penile bulb, were delineated and reviewed according to our institutional protocols by radiation oncologists. The CT and MR images were fused to the prostate, and the prostate and penile bulb were manually delineated on the CT and MR images. The remaining organs were delineated on the CT images without the MR images. MVision AI Contour+ was used to perform DL-based automated segmentation. The dice similarity coefficient (DSC) and 95% Hausdorff distance (HD95%) were evaluated for comparison with manual delineations.

RESULTS

The mean DSC values for the prostate, SV, bladder, rectum, both femoral heads, and penile bulb were 0.86, 0.80, 0.96, 0.92, 0.97, and 0.64, respectively. The HD95% for all the organs was less than 3 mm.

CONCLUSIONS

The commercial DL-based auto segmentation solution provided high-quality contours in patients with prostate cancer.

Для цитирования: Miura Hideharu, Ishihara Soichiro, Kenjo Masahiro, Nakao Minoru, Ozawa Shuichi, Kagemoto Masayuki. Evaluation of the accuracy of automated segmentation based on deep learning for prostate cancer patients.. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2024. DOI: 10.1016/j.meddos.2024.09.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.