DOI 10.1016/j.amjoto.2021.103217

Медицинская библиотека · American journal of otolaryngology · 2021

Biomechanical properties of the ex vivo porcine trachea: A benchmark for three-dimensional bioprinted airway replacements.

Kaye Rachel, Cao Angela, Goldstein Todd, Grande Daniel A, Zeltsman David, Smith Lee P

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Combining tissue engineering and three-dimensional (3D) printing may allow for the introduction of a living functional tracheal replacement graft. However, defining the biomechanical properties of the native trachea is a key prerequisite to clinical translation. To achieve this, we set out to define the rotation, axial stretch capacity, and positive intraluminal pressure capabilities for ex vivo porcine tracheas.

STUDY

DESIGN

Animal study.

MATERIALS AND

METHODS

Six full-length ex vivo porcine tracheas were bisected into 5.5 cm segments. Maximal positive intraluminal pressure was measured by sealing segment ends with custom designed 3D printed caps through which a pressure transducer was introduced. Axial stretch capacity and rotation were evaluated by stretching and rotating the segments along their axis between two clamps, respectively.

RESULTS

Six segments were tested for axial lengthening and the average post-stretch length percentage was 148.92% (range 136.81-163.48%, 95% CI 153-143%). The mean amount of length gain achieved per cartilaginous ring was 7.82% (range 4.71-10.95%, 95% CI 6.3-9.35%). Four tracheal segments were tested for maximal positive intraluminal pressure, which was over 400 mmHg. Degree of rotation testing found that the tracheal segments easily transformed 180° in anterior-posterior bending, lateral bending, and axial rotational twisting.

CONCLUSIONS

We define several biomechanical properties of the ex vivo porcine trachea by reporting the rotation, axial stretch capacity, and positive intraluminal pressure capabilities. We hope that this will aid future work in the clinical translation of 3D bioprinted airway replacement grafts and ensure their compatibility with native tracheal properties.

Для цитирования: Kaye Rachel, Cao Angela, Goldstein Todd, Grande Daniel A, Zeltsman David, Smith Lee P. Biomechanical properties of the ex vivo porcine trachea: A benchmark for three-dimensional bioprinted airway replacements.. American journal of otolaryngology. 2021. DOI: 10.1016/j.amjoto.2021.103217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.