DOI 10.1007/s10096-020-03972-y
Combined throat/nasal swab sampling for SARS-CoV-2 is equivalent to nasopharyngeal sampling.
Аннотация
PURPOSE: PCR on a nasopharyngeal sample is the reference method for the detection of SARS-nCoV-2. However, combined throat/nasal sampling as a testing method has several advantages. We compared the combined throat/nasal sampling with nasopharyngeal sampling for detection of SARS-CoV-2 in healthcare workers suspected of COVID-19.
METHODS
In 107 healthcare workers with symptoms of COVID-19, combined throat/nasal sampling and nasopharyngeal sampling was performed. Detection of SARS-CoV-2 was performed by RT-PCR targeting.
RESULTS
A total of 80 healthcare workers (74.8%) tested negative with both sampling methods, and 25 healthcare workers (23.4%) tested positive with both sampling methods. There were two discrepant results with positive PCR in combined throat/nasal swabs and negative PCR in nasopharyngeal swabs (1.9%). The κ index for concordance between the 2 sampling methods was high (0.95). The median cycle threshold (Ct) value of PCR on nasopharyngeal samples was significantly lower than the Ct value of PCR on combined throat/nasal samples (19 (IQR 17-20) versus 21 (IQR 18-29) cycles, p value 0.01).
CONCLUSION
Combined throat/nasal swabs yield a similar sensitivity to detect SARS-CoV-2 as nasopharyngeal swabs and are a good alternative sampling method, despite a lower Ct value for the nasopharyngeal samples.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.