MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmir.2016.11.003

Медицинская библиотека · Journal of medical imaging and radiation sciences · 2016

Interobserver Variability in the Delineation of Gross Tumour Volume and Specified Organs-at-risk During IMRT for Head and Neck Cancers and the Impact of FDG-PET/CT on Such Variability at the Primary Site.

Gudi Shivakumar, Ghosh-Laskar Sarbani, Agarwal Jai Prakash, Chaudhari Suresh, Rangarajan Venkatesh, Nojin Paul Siji, Upreti Rituraj, Murthy Vedang, Budrukkar Ashwini, Gupta Tejpal

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess interobserver variability (IOV) in the delineation of structures during intensity-modulated radiation therapy for head and neck squamous cell carcinoma and the impact of fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) on such variability at the primary site.

METHODS

Three experienced head-neck radiation oncologists, blinded to each other, delineated the primary site gross tumour volume (GTV) and specified organs-at-risk (OARs) viz parotid gland, spinal cord, and cochlea in 10 patients with pharyngolaryngeal cancers suited for definitive intensity-modulated radiation therapy. IOV was assessed by concordance index (CI), Dice similarity coefficient (DSC), and Fleiss' kappa. Subsequently, the observers refined their corresponding GTVs incorporating information from FDG-PET/CT. The impact of FDG-PET/CT on variability of GTV was assessed by comparing the overlap indices with and without FDG-PET/CT using paired 't' test.

RESULTS

There was moderate IOV in the delineation of GTV as evidenced by mean CI, DSC, and Fleiss' kappa of 0.41, 0.57, and 0.56, respectively. The use of FDG-PET/CT improved consistency of target volume delineation with resultant improvement in the overlap indices (mean CI, DSC, and Fleiss' kappa of 0.54, 0.69, and 0.69, respectively) that was statistically significant (P < .001). There was good agreement between the three observers for delineation of spinal cord and parotid glands. Concordance was worst for the cochlea.

CONCLUSION

This study demonstrates the presence of moderate IOV between three experienced head and neck radiation oncologists in an academic institutional setting for the delineation of GTV. The use of FDG-PET/CT for target volume delineation results in significant reduction of such variability.

Для цитирования: Gudi Shivakumar, Ghosh-Laskar Sarbani, Agarwal Jai Prakash, Chaudhari Suresh, Rangarajan Venkatesh, Nojin Paul Siji, Upreti Rituraj, Murthy Vedang, Budrukkar Ashwini, Gupta Tejpal. Interobserver Variability in the Delineation of Gross Tumour Volume and Specified Organs-at-risk During IMRT for Head and Neck Cancers and the Impact of FDG-PET/CT on Such Variability at the Primary Site.. Journal of medical imaging and radiation sciences. 2016. DOI: 10.1016/j.jmir.2016.11.003.