Detection of low levels of SARS-CoV-2 RNA from nasopharyngeal swabs using three commercial molecular assays.

Lowe Christopher F, Matic Nancy, Ritchie Gordon, Lawson Tanya, Stefanovic Aleksandra, Champagne Sylvie, Leung Victor, Romney Marc G

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

In response to the COVID-19 pandemic, commercial molecular assays for SARS-CoV-2 testing have been rapidly developed and broadly deployed in laboratories worldwide. Although these assays have been reported to correlate well, we sought to compare the Xpert® Xpress SARS-CoV-2 to the cobas® SARS-CoV-2 or the Lightmix® Modular SARS and Wuhan CoV E-gene assay for nasopharyngeal (NP) swabs with low levels of SARS-CoV-2 RNA. Thirty-seven NP swabs were studied, including 10 samples with a moderate cycle threshold (Ct) between 30-33.9, and 22 with Ct≥34, and 5 negative for SARS-CoV-2. Overall concordance on initial comparison was 86.5 % (32/37), which was 100 % concordance for samples with Ct values ranging between 30-33.9. Discordance amongst samples showing a Ct ≥34 was 22.7 % (5/22). Endpoint value analysis on the Xpress SARS-CoV-2 within the discordant samples noted two with an endpoint value >5, which were detected by the cobas® or Lightmix®. Testing of SARS-CoV-2 on the three commercial assays was comparable for NP swabs with moderate Ct values, while high Ct values were less concordant. Importantly, analysis of Xpert® endpoint values improved interpretation of discrepant results.

Для цитирования: Lowe Christopher F, Matic Nancy, Ritchie Gordon, Lawson Tanya, Stefanovic Aleksandra, Champagne Sylvie, Leung Victor, Romney Marc G. Detection of low levels of SARS-CoV-2 RNA from nasopharyngeal swabs using three commercial molecular assays.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2020. DOI: 10.1016/j.jcv.2020.104387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.